beautypg.com

$padblk pad block size, $padfwd pad forward character – Horner APG XLt OCS HE-GSM04 User Manual

Page 56

background image

PAGE 56

GPRS / GSM MODEM Configuration

MAN4005-04-EN



20. $PADBLK PAD Block Size

$PADBLK

PAD Block Size

Command Function

This command allows the user to query/set the PAD block size.

Command Functional
Group

Enfora Specific

Command Format Query
Response

AT$PADBLK=?
PADBLK: (3-512)
OK

Write Format
Response

AT$PADBLK =<block size >
OK

Read Format
Response

AT$PADBLK?
$PADBLK: <block size>

Execution Format
Response

N/A
N/A

Parameter Values

PAD data will be created at the requested

PAD block size (number of bytes) unless an enabled forward character or PAD
timeout forces the data to be sent out at a smaller block size. Block size does
NOT include the IP or TCP/UDP header size.


21. $PADFWD PAD Forward Character

$PADFWD

PAD Forward Character

Command Function

This command allows the user to query/set the PAD forward character. If PAD
forward is enabled via AT$PADCMD, receipt of this character will immediately
forward all currently buffered PAD data.

Command Functional
Group

Enfora Specific

Command Format Query
Response

AT$PADFWD =?
$PADFWD: (0-ff)
OK

Write Format
Response

AT$PADFWD =<forward character>
OK

Read Format
Response

AT$PADFWD?
$PADFWD: <forward character>

Execution Format
Response

N/A
N/A

Parameter Values

Hex representation of user selected forward character. Default forward character
is 0D (Carriage return).





Page 56 of 62 ECN # 956

This manual is related to the following products: