Ky5 !;n, Op( npn npn pnp, Eof eon – Ashcroft GC35 - Pressure Sensor User Manual
Page 11: E(o eof, F;l f-1, Llri, Et[ p5i, 00 lr0, D0.00, A0.0

11
P5I
Function Setting Mode
Filter Setting
Decimal Point Position
Display Unit Setting
Select Comparator Mode
LED Ring Feature Setting
Comparator Operation
Selection
Measurement Mode
Press 3 sec.
or longer
Press 3 sec.
or longer
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
After 1 second
kY5
kY5
!;n
Select with
X
W
keys
Select with
X
W
keys
Select with
X
W
keys
Message displayed
Current setting
Hysteresis
Window comparator
After 1 second
OP(
npn
npn
pnp
Message displayed
Current unit
setpoint
NPN output
PNP output
Select with
X
W
keys
EoF
Eon
Power-save OFF
Power-save ON
e(O
Message Display
Current Setting
e(O
eOf
After 1 second
f;l
f-1
Message displayed
Current setting
After 1 second
lRg
Message Display
Current Setting
L
lRI
After 1 second
Select with
X
W
keys
ET[
P5I
psi, bar or mPa
Display Scaling
UN;
Message Display
Current Setting
u
After 1 second
Select with
X
W
keys
Power-save setting
(Display Scaling)
Set Offset Value
(Display Scaling Set)
Full Scale Value
Pressure when the
analog is at zero point
Pressure when the
analog is at span point
f-0
Filter off
f-1
Time constant 25ms
f-2
Time constant 250ms
f-3
Time constant 2.5s
f-4
Time constant 5s
f-5
Time constant 10s
Select with
X
W
keys
Set Any Desired Position Within the
–100 to 150% range with the
X
W
keys
Set Any Desired Position Within the
–100 to 150% range with the
X
W
keys
X
W
Key to Select Between
(–)1999~(+)9999
X
W
Key to Select Between
(–)1999~(+)9999
0
0.0
0.000
0.00
Lr0
No LED interlock
Lr1
Comparator 1 is
interlocked with LED
Lr3
Comparator 1 & 2 are
interlocked with LED
Lr2
Comparator 2 is
interlocked with LED
d-p
Message Display
Current Setting
d
0.00
After 1 second
d-l
Message Display
Current Setting
d
0.00
After 1 second
d-K
Message Display
Only in Output Selection
Display Scaling
Current Setting
d
0.00
After 1 second
A-L
Message Display
Current Setting
a
0.0
After 1 second
a
Message Display
Current Setting
a-k
100.0
After 1 second
D I S P L AY S E T T I N G
A N A LO G O U P U T S CA L I N G
(n
~P
Energy-Saving Mode Setting
The unit is equipped with automatic display turn-off feature. If user wishes to turn-on the display
only when reading the display, or to use the unit mainly for an electrical output reading, this fea-
ture can be used.
LED Ring Operation Setting
Ⅺ
lr0 LED ring is off.(no linkage)
Ⅺ
Lr1
LED ring turns Red when comparator 1 is ON, and turn Blue or Green when OFF.
Ⅺ
Lr2 LED ring turns Red when comparator 2 is ON, and turn Blue or Green when OFF.
(Feature is only available for 2 comparator output option)
Ⅺ
Lr3 LED ring turns Red when comparator 1 or 2 is ON, and turns Blue or Green when OFF.
(Feature is only available for 2 comparator output option)
(LED Ring: Blue when OFF: NPN output selected. Green when OFF: PNP output selected)