beautypg.com

Princeton Tec EOS TACTICAL MPLS User Manual

Tactical mpls

background image

EOS

TM

TACTICAL

MPLS

Operating and Maintenance

Instructions

Notice d’utilisation et d’entretien

Bedienungsanleitung

Battery Installation – See Battery Installation Diagram

3 AAA

Alkaline (LR03)

Rechargeable NiCad or NiMH

Princeton Tec cares about the environment and
recommends recycling batteries. For more information
about battery recycling, please go to:
www.batteryrecycling.com
Observe proper battery polarity when installing the
batteries. Improper installation of the batteries will
damage the light and void the warranty.

WARNING

Never mix fresh and used batteries.

• Never mix fresh and used batteries.
• Never mix different battery brands or chemistry types.
• Always remove drained batteries immediately.
• Remove batteries during long periods of storage.
NOTE: Lithium batteries offer extended constant
brightness time, extreme cold weather performance, and
are lighter weight. Rechargeable NiCad or NiMH batteries
may result in reduced brightness due to lower nominal
voltage.
The Tactical Eos battery compartment has a waterproof
seal. It is important to keep this seal free from dirt and
away from harsh chemicals in order to preserve
waterproof integrity. Inspect the seal every time batteries
are changed. If dirt is present, wipe gently with a damp
cotton swab and mild soap until dirt is removed.
NOTE: Some battery types can emit hydrogen gas,
which can create an explosion potential in sealed
devices if it is not vented or removed. The Eos is
equipped with a platinum catalyst to remove this gas.
Upon severe impact, the catalyst could fracture. If you
notice a rattling sound in the headlamp or gray particles
in the battery compartment, do not use the headlamp.
See the warranty and return policy for more information.

Switch Operation – See Switch Operation diagram
Modes (High, medium, low, and flash) are selected by
pressing and releasing the button within 1.5 seconds of
the previous button press.
There are two ways to turn the Tactical Eos off. You can
cycle through the modes until you reach off or if more
than two seconds has passed since the previous button
press the next press of the button will turn the light off.

**The times listed on the rear of the package assume you

have start with fresh batteries and use only one mode.

NVG Mounting System
To attach the MPLS Headlamp to the NVG Shroud:

1. Slide the bracket arm into the NVG Shroud adapter

plate, making sure the pull tab is above the lip of the

adapter plate and that the male grooves on the bottom

of the bracket arm are aligned inside the female

grooves on the bottom of the adapter plate.
2. Push the bracket arm securely into place, ensuring

that the pull tab audibly clicks over the lip of the NVG

Shroud adapter plate.
3. Your MPLS Headlamp should now be secured in the

NVG Shroud. You can rotate the headlamp to focus

your light source accordingly.

To remove the MPLS headlamp from the NVG Shroud:
1. Remove the NVG Mount from your helmet.

2. Push up slightly on the bottom of the light housing.
3. While pushing upward, use the tool on the provided

headstrap to press the tab of the arm bracket towards the

headlamp housing, so that it disengages from the NVG

Shroud adapter plate.
4. Slide the headlamp unit out of the NVG Shroud

adapter plate.
To attach the MPLS Headlamp to the Butterfly Mount:

1. Slide the bracket arm into the Butterfly Mount, making

sure the pull tab is above the lip of the mount and that the

male grooves on the bottom of the bracket arm are
aligned inside the female grooves on the bottom of

the mount.
2. Push the bracket arm securely into place, ensuring that

the pull tab audibly clicks over the lip of the Butterfly Mount.
3. Your MPLS Headlamp should now be secured in the

Butterfly Mount. The mount can be attached to the

provided headstrap, MOLLE straps, or any 1” webbing.

You can rotate the headlamp to focus your light source

accordingly.

To remove the MPLS headlamp from the Butterfly Mount:

1. Push up slightly on the bottom of the light housing.
2. While pushing upward, use the tool on the provided

headstrap to press the tab of the arm bracket towards the

headlamp housing, so that it disengages from the

Butterfly Mount.
3. Slide the headlamp unit out of the Butterfly Mount.

Troubleshooting
If the Eos Tactical fails to light:

Check the batteries for proper installation.

Replace batteries if proper installation is confirmed.

Check the light for water contamination on the circuit

board. The light will resume normal operation once the

water is shaken or blown out and the light is left open until

completely dry. If the light has been contaminated with

salt water, flush the unit with fresh water and dry as

described above.

USA– International 5-Year Warranty
WARRANTY – Princeton Tec warrants this product to be

free from defects in workmanship and materials under

normal use for as long as you own this product. This

warranty covers all of the component parts of the product

except batteries. This warranty does not cover deterioration

due to normal wear or damage due to misuse, alteration,

negligence, accidents, or unauthorized repair. Princeton Tec

will repair or replace parts which are defective in

workmanship or materials.
Your authorized Princeton Tec Dealer and Princeton Tec are

the only facilities authorized to repair the product. After (3)

unsuccessful attempts (within the warranty period) to repair

the product, you have the right to elect replacement of the

product or a refund of the purchase price less allowance for

use of the product. NO INCIDENTAL OR CONSEQUENTIAL

DAMAGES ARE INCLUDED IN THIS WARRANTY. (Some

states do not allow the exclusion or limitation of incidental or

consequential damages, so the above limitations or

exclusions may not apply to you.) This warranty gives you

specific legal rights, and you may also have other rights

which vary from state to state.
Princeton Tec reserves the right to change product

specifications without notice.
Return Policy
If your light fails to operate, follow these simple steps:

1. Check batteries. Replace if necessary.
2. Contact Princeton Tec customer service at 800-257-9080

to request an RMA number to send your light in for repair

or replacement. No warranty repairs will be accepted

without an RMA number.

3) Return the light without batteries to: Princeton Tec, 5198

Rt. 130, Bordentown, NJ 08505. Postage due and freight

collect items will not be accepted.

Princeton Tec

PO Box 8057,

Trenton, NJ 08650

Phone: 609-298-9331

Fax: 609-298-9601

www.princetontec.com

© 2013 Princeton Tec

50H

121H

10H

115H

113H

100H

1H

30

45

60

Switch Operation

Opération de commutation

Betriebsartenschalter