Princeton Tec REMIX PRO User Manual
English
www
.princetontec.com
ENGLISH
Figure 1 – Switch Operation
Opération de commutation
Betriebsartenschalter
* Princeton Tec calculates total burn time as the time it takes for the light source to produce a
minimum of 0.25 lux at 2 meters. 0.25 lux is about the equivalent of a full moon on a clear night.
* Princeton Tec berechnet die Gesamtbrenndauer bezogen auf eine von der Stirnlampe erzeugte
minimale Beleuchtungsstärke von 0,25 Lux in 2 Meter Abstand. 0,25 Lux entsprechen in etwa
der Beleuchtungsstärke des Vollmonds in einer klaren Nacht.
* Princeton Tec définit la durée totale d’éclairage comme le temps nécessaire à la source
lumineuse pour produire un minimum de 0,25 lux à 2 mètres. 0,25 lux équivaut à peu près à la
luminosité d’une pleine lune dans un ciel nocturne dégagé.
REMIX
®
PRO
LED HEADLAMP
Operating and Maintenance
Instructions
Notice d’utilisation et d’entr
etien
Bedienungsanleitung
Battery Installation – See Battery Installation Diagram
•
1 CR123 lithium battery
Princeton Tec cares about the environment and
recommends recycling batteries. For more information
about battery recycling, please go to:
www.batteryrecycling.com
To install the batteries, unlatch the battery door. Open
the Remix Pro case by popping the door latch over the
catch and rotate the door open.
The positive terminal is down when you insert the
battery into the case.
Observe proper battery polarity when installing the
batteries. Improper installation of the batteries will
damage the light and void the warranty.
Rotate the door to the closed position, squeeze the
body between your forefingers and thumb to snap the
door latch over the catch.
Light Sources
3x 5mm LEDs or Maxbright LED
The light always starts on the “5mm LEDs on low
brightness”, no matter which light source or brightness
setting you were previously on prior to turning the light off.
The Remix Pro has two ways to turn the light off.
1. You can press the switch continuously until the light
turns off.
2. or if more than 1.6 seconds has passed (since your
last button press) the light will turn off on the next
press.
Switching from the 5mm to the Maxbright LED –
The Remix Pro has two light sources to choose from,
three Ultrabright LEDs or a Maxbright LED. Each light
source has two modes (High and Low).
To switch between light sources, press and hold the
button down until the light source switches to the
desired source. As soon as it switches release the
button.
NOTE: If you keep the button pressed the light will
continue to switch back and forth between the 5mm
and Maxbright LED (on low light settings) until you
release the button.
Once you have found your desired light source, you
now can select different brightness levels. Your light
will start on “low output”. To change to “high output”
you must press the button again in less then 1.6
seconds from the previous press. Any additional delay
will cause the light to turn off after the next button
press.
One final note about the light function – If you have the
light turned on, (and more than 1.6 seconds has
passed since your last button press) and you press
and hold the button down to switch light sources, you
will be in darkness for about one second as the light
sees this press as a signal to turn the light off and
switch to the other light source simultaneously.
Troubleshooting
If the Remix Pro fails to light:
•
Check the batteries for proper installation.
•
Replace batteries if proper installation is confirmed.
•
Check the light for water contamination on the
circuit board. The light will resume normal operation
once the water is shaken or blown out and the light is
left open until completely dry. If the light has been
contaminated with salt water, flush the unit with fresh
water and dry as described above.
USA– International 5-Year Warranty
WARRANTY – Princeton Tec warrants this product to
be free from defects in workmanship and materials
under normal use for as long as you own this product.
This warranty covers all of the component parts of the
product except batteries. This warranty does not cover
deterioration due to normal wear or damage due to
misuse, alteration, negligence, accidents, or
unauthorized repair. Princeton Tec will repair or replace
parts which are defective in workmanship or materials.
Your authorized Princeton Tec Dealer and Princeton
Tec are the only facilities authorized to repair the
product. After (3) unsuccessful attempts (within the
warranty period) to repair the product, you have the
right to elect replacement of the product or a refund of
the purchase price less allowance for use of the
product. NO INCIDENTAL OR CONSEQUENTIAL
DAMAGES ARE INCLUDED IN THIS WARRANTY.
(Some states do not allow the exclusion or limitation of
incidental or consequential damages, so the above
limitations or exclusions may not apply to you.) This
warranty gives you specific legal rights, and you may
also have other rights which vary from state to state.
Princeton Tec reserves the right to change product
specifications without notice.
Return Policy
If your light fails to operate, follow these simple steps:
1) Check batteries. Replace if necessary.
2) Contact Princeton Tec customer service at
800-257-9080 to request an RMA number to send your
light in for repair or replacement. No warranty repairs
will be accepted without an RMA number.
3) Return the light without batteries to: Princeton Tec,
5198 Rt. 130, Bordentown, NJ 08505. Postage due
and freight collect items will not be accepted.
Princeton Tec
PO Box 8057,
Trenton, NJ 08650
Phone: 609-298-9331
Fax: 609-298-9601
www.princetontec.com
© 2013 Princeton Tec
Figure 2 – Battery Replacement
Remplacement des piles
Einlegen der Batterien
press 1x = Low
press 2x = High
1 MAXBRIGHT
LED
DISTANCE (Meters) 16
28
53
73
LOW
7H
HIGH
4H
LOW
40H
HIGH
5H
DISTANCE (Meters) 16
28
28
73
to switch between light
sources, press and hold
button (1-2 seconds)
3
1
2
press 1x = Low
press 2x = High
3 ULTRABRIGHT
LEDs