PR0 – MICR IP Address Fixed Value (Ethernet Only)
This sets the fixed IP address for the MICR unit. For example:
PR0=192.11.12.127
PR1 – MICR IP Address Source (Ethernet Only)
PR1=0
- sets unit to configure MICR IP using DHCP
PR1=1
- sets unit to use fixed value (see PR0)
Note
This must be set to DHCP if any other configuration is to be obtained via DHCP.
PR2 – MICR IP Subnet Mask Fixed Value (Ethernet Only)
This sets the fixed IP subnet mask used by the MICR unit. For example:
PR2=255.255.255.0
PR3 – MICR Subnet Mask Source (Ethernet Only)
PR3=0
- sets unit to configure the subnet mask using DHCP
PR3=1
- sets unit to use fixed value (see PR2)
PR4 – Gateway IP Address Fixed Value (Ethernet Only)
This sets the fixed IP address for the gateway/router. For example:
PR4=192.11.12.127