MagTek MINI MICR WEDGE User Manual
Page 40

MINI MICR WEDGE with 3-Track MSR
32
Fmt 52xx:
'T' [transit] 'T' [acct #] 'A' [check #]
• [transit]:
- all characters in the field
-
remove
dashes
• [acct #]:
- maximum of xx characters; when xx=00 all characters are sent
- remove spaces and dashes
• [check #]:
- all characters in the field
- remove dashes and spaces
Fmt 53xx:
'/' [transit] '/' [acct #] '/' [check #] '/' [tpc] '/' [status] '/'
• [transit]:
- all characters in the field
-
remove
dashes
• [acct #]:
- maximum of xx characters; when xx=00 all characters are sent
- remove spaces and dashes
• [check #]:
- all characters in the field
• [tpc]:
- all characters in the field
• [status]:
- this is a programmable option that must be enabled (See Table 4-4)
Fmt 54xx:
[transit] [acct #] [check #] [status]
• [transit]:
- always 12 characters, zero filled
-
remove
dashes
• [acct #]:
- always xx characters, zero filled;
when xx=00 all characters are sent
- remove spaces and dashes
• [check #]:
- always 12 characters, zero filled
- remove dashes and spaces
• [status]:
- this is a programmable option that must be enabled (See Table 4-4)
Fmt 55xx:
'C' '/' [acct #] '/' [transit] '/' [check #] '/' 0000000000
• [acct #]:
- always xx characters, zero filled;
when xx=00 all characters are sent
- remove spaces and dashes
• [transit]:
- all characters in the field
-
remove
dashes
• [check #]:
- always 6 characters, zero filled
- remove dashes and spaces