Appendix A. Format List
25
Fmt 20xx:
[transit] [acct #]
• [transit]:
- all characters in the field
-
keep
dashes
• [acct #]:
- maximum of xx characters; when xx=00 all characters are sent
- replace spaces and dashes with zeros
• [check #]:
- all characters in the field
Fmt 21xx:
[transit] [acct #] [check #]
• [transit]:
- all characters in the field
-
keep
dashes
• [acct #]:
- always xx characters, zero filled;
when xx=00 all characters are sent
- replace spaces and dashes with zeros
• [check #]:
- all characters in the field
Fmt 22xx:
[bank #] [acct #] [check #]
• [bank #]:
- all characters in the field
-
keep
dashes
• [acct #]:
- always xx characters, zero filled;
when xx=00 all characters are sent
- replace spaces and dashes with zeros
• [check #]:
- all characters in the field
Fmt 23xx:
[error #] [transit] [acct #] [check #] 'S'
• [error #]:
- one digit, always present
- '0' read OK
- '1' read error: bad char empty field, invalid length, validation
• [transit]:
- always 9 characters, zero filled
-
keep
dashes
• [acct #]:
- always xx characters, trailing spaces;
when xx=00 all characters are sent
- remove spaces and dashes
• [check #]:
- always 6 characters, zero filled
- remove spaces and dashes