Swa parameters, Wedge type, Send data after error – MagTek MINI MICR WEDGE User Manual
Page 18: Swa - switch a command, A parameters

MINI MICR WEDGE with 3-Track MSR
10
When sending data, all 8 bits must be provided. The MICR Reader will execute the command but
it will not reply. The SWA options are saved immediately.
If no data is sent, the MICR Reader responds with the current settings for SWA.
Table 4-1. SWA Command
BITS PARAMETERS
7
6
5
4
3
2
1
0
1
1
0
Wedge AT
0
1
0
Wedge NCR
0
0
Send data after error: Yes
0
1
Send data after error: No
0
Keypad: calculator (Wedge NCR only)
1
Keypad: telephone (Wedge NCR only)
0
0
These bits are always set to 0
SWA PARAMETERS
The SWA functions are listed in Table 4-1 and described below.
Wedge Type
The Wedge type can be for the IBM AT or NCR 7052/7053 cash registers.
Send Data After Error
The request Send Data After Error specifies whether the MICR Reader will return data to the Host
after a read error. If YES is selected and the MICR Reader detects a read error, the MICR Reader
will still send the data back to the Host. If NO is selected and the MICR Reader finds an error, it
will discard the data and nothing will be sent. The error conditions are listed in Table 4-2.