Keypad type, Telephone calculator, Send data after error – MagTek MINI MICR WEDGE User Manual
Page 19: Table 1-1. specifications

Section 4. Commands
11
Table 4-2. Error and Status Codes
PRIORITY CODE
TYPE
DESCRIPTION
9
01
Error
No MICR data: no transit and no account found
8 09
Status
Mexican
check
7 08
Status
Canadian
check
6
05
Error
Transit error: No transit, bad character, bad length,
bad check digit
5
07
Error
Account error: No account, bad character
4
04
Error
Check # error: Bad character in check number
4
04
Status
No check number
3
03
Status
Low MICR signal, good read
2 10
Status
Business
check
1
11
Status
Amount field present
0
00
Status
No error, check OK
Notes:
•
The LED will turn red on all error conditions.
•
The absence of a check number is not considered an error.
•
If a multiple error condition occurs, the error or status code with the highest priority is
reported.
•
All unreadable MICR characters are transmitted as a “?” ASCII character (hex 3F), except for
Format 00xx (See Appendix A).
Keypad Type
The Keypad selection is for the Wedge NCR only. The selection is the calculator type of layout or
telephone layout. Both are shown in Figure 4-1.
Telephone
Calculator
Figure 4-1. Keypad Types
1
2
3
7
8
9
4
5
6
0
4
5
6
1
2
3
7
8
9
0