Send status after data, Swc - switch c command, Enter> key options send status after data – MagTek MINI MICR WEDGE User Manual
Page 23

Section 4. Commands
15
Combinations of these options as shown in Table 4-3 are as follows:
Do not Send – The MICR Reader will not send the
Default Single – The MICR Reader will use the default scan code for a one-key
Default Double – The MICR Reader will used two default scan codes for a two-key
Custom Single – The keyboard has a one-key
default position. The scan code must be programmed into the MICR Reader.
Custom Double – The keyboard has a two-key
default position. The scan codes must be programmed into the MICR Reader
Send Status After Data
The Send Status After Data option makes the MICR Reader append a two-digit error/status code
to the end of the MICR data. For most formats (See Appendix A) the error/status code will
always be preceded by a forward slash (/). The error/status codes are listed in Table 4-2.
For example, if a Canadian check (code 08) is read and had no errors, and the MICR data is
“1234567890”, then the message from the MICR Reader will look like this:
MICR Data: 1234567890/08
The status code is always at the end of the data, not the end of the message. For example, using
the above conditions, with the message format set to send
the MICR Reader will look like this:
MICR Data:
SWC - SWITCH C COMMAND
The SWC command controls miscellaneous functions, shown in Table 4-5. The data for this
command consists of 8 ASCII bits (“0” = hex 30 and “1” = hex 31).
To execute, send the SWC command as follows:
SWC 01010101
(with data)
or
SWC
(without data)