MagTek MINI MICR WEDGE User Manual
Page 34

MINI MICR WEDGE with 3-Track MSR
26
Fmt 24xx:
[transit] 'T' [acct #] 'A' [check #] 'C' [amount] '$'
• [transit]:
- all characters in the field
-
keep
dashes
• [acct #]:
- maximum of xx characters; when xx=00 all characters are sent
- remove spaces and dashes
• [check #]:
- always 6 characters, zero filled
• [amount]:
- all characters in the field
Fmt 25xx:
'M' 'C' [transit] 'D' [acct #] 'E' [check #]
• [transit]:
- all characters in the field
- remove dashes and keep spaces (contig spcs = 1 spc)
- if the field is empty, remove 'C'
• [acct #]:
- include leading characters
- maximum of xx characters; when xx=00 all characters are sent
- remove dashes and keep all spaces
- if the field is empty, remove 'D'
• [check #]:
- all characters in the field
- if the field is empty, remove 'E'
Fmt 26xx: [acct
#]
• [acct #]:
- work with characters in acct and transit fields
- a window of xx characters; xx must be greater than 00
- remove spaces and dashes
Fmt 27xx: [acct
#]
• [acct #]:
- work with characters in the acct field only
- a window of xx characters; xx must be greater than 00
- remove spaces and dashes
Fmt 28xx: [acct
#]
• [acct #]:
- work with characters in the acct field only
- a window of xx characters; xx must be greater than 00
- minimum of 6 digits, fill with zeros if necessary
- remove spaces and dashes