8 power down the device / cool the tipper heater, Power down the device / cool the tipper heater, 3 - preventive maintenance procedure – MagTek EC2000 99875651 User Manual
Page 13

3 - Preventive Maintenance Procedure
ExpressCard 2000| Instant Issuance Card Personalization System | Preventive Maintenance Procedure
Page 13
Figure 3-7 - Run a Thin Bead of Tri-Flow Along the Top of the Shaft (TOP LEFT VIEW)
7) Use the drive belt to move the XY transport to the front of the device, then to the rear again to spread
the Tri-Flow along the length of the shaft.
8) If you have applied too much Tri-Flow to the shaft, some may drip off the shaft. If this happens, dab
off the excess with a clean, lint free cloth.
3.8 Power Down the Device / Cool the Tipper Heater
1) Navigate to
Menu
>
Settings
>
Tipper
to open the
Tipper
page.
2) Press the
Set Heater OFF
button to turn off the tipper heater.
3) Note the value under Current Tipper Temp. If the tipper temperature is 50 degrees Centigrade or
hotter, the tipper heater is not safe to touch.
4) Take note of the current time, and plan your work to allow enough time for the tipper heater to cool,
which can take up to 15 minutes. You may be able to use compressed air to cool it more quickly.
5) Power down the device.