beautypg.com

Ss_tk3_iso_aba property (kb), Ss_tk3_aamva property (kb), Ss_tk3_7bits property (kb) – MagTek USB MagnePrint Swipe Reader with Encryption User Manual

Page 41

background image

Section 4. USB Communications

33

SS_TK3_ISO_ABA PROPERTY (KB)

Property ID:

8

Property Type:

Byte

Length: 1

byte

Get Property:

Yes

Set Property:

Yes

Default Value:

2B (hex) ‘+’

Description:

This character is sent as the track 3 start sentinel for cards that have track 3
encoded in ISO/ABA format. If the value is 0 no character is sent. If the
value is in the range 1 – 127 then the equivalent ASCII character will be sent.

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.


SS_TK3_AAMVA PROPERTY (KB)

Property ID:

9

Property Type:

Byte

Length: 1

byte

Get Property:

Yes

Set Property:

Yes

Default Value:

23 (hex) ‘#’

Description:

This character is sent as the track 3 start sentinel for cards that have track 3
encoded in AAMVA format. If the value is 0 no character is sent. If the
value is in the range 1 – 127 then the equivalent ASCII character will be sent.

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.


SS_TK3_7BITS PROPERTY (KB)

Property ID:

10 (0x0A)

Property Type:

Byte

Length: 1

byte

Get Property:

Yes

Set Property:

Yes

Default Value:

26 (hex) ‘&’

Description:

This character is sent as the track 3 start sentinel for cards that have track 3
encoded in 7 bits per character format. If the value is 0 no character is sent. If
the value is in the range 1 – 127 then the equivalent ASCII character will be
sent.

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.