Data length, Data, Result code – MagTek USB MagnePrint Swipe Reader with Encryption User Manual
Page 33: Get and set property commands

Section 4. USB Communications
25
Value Command
Number
Description
0
GET_PROPERTY
Gets a property from the device
1
SET_PROPERTY
Sets a property in the device
2
RESET_DEVICE
Resets the device
3
GET_KEYMAP_ITEM
Gets a key map item (KB only)
4
SET_KEYMAP_ITEM
Sets a key map item (KB only)
5
SAVE_CUSTOM_KEYMAP
Saves the custom key map (KB only)
7
LOAD DUKPT INITIAL KEY
Loads the initial DUKPT Key scheme
8
REINITIALIZE DUKPT KEY
Reinitializes the DUKPT Key scheme
9
GET_DUKPT_KSN
Reports DUKKPT KSN and Counter
DATA LENGTH
This one-byte field contains the length of the valid data contained in the Data field.
DATA
This multi-byte field contains command data if any. Note that the length of this field is fixed at
22 bytes. Valid data should be placed in the field starting at offset 2. Any remaining data after
the valid data should be set to zero. This entire field must always be set even if there is no valid
data. The HID specification requires that Reports be fixed in length. Command data may vary
in length. Therefore, the Report should be filled with zeros after the valid data.
RESULT CODE
This one-byte field contains the value of the result code. There are two types of result codes:
generic result codes and command-specific result codes. Generic result codes always have the
most significant bit set to zero. Generic result codes have the same meaning for all commands
and can be used by any command. Command-specific result codes always have the most
significant bit set to one. Command-specific result codes are defined by the command that uses
them. The same code can have different meanings for different commands. Command-specific
result codes are defined in the documentation for the command that uses them. Generic result
codes are defined in the following table.
Value Result
Code
Description
0
SUCCESS
The command completed successfully.
1
FAILURE
The command failed.
2
BAD_PARAMETER
The command failed due to a bad
parameter or command syntax error.
GET AND SET PROPERTY COMMANDS
The Get Property command gets a property from the device. The Get Property command
number is 0.
The Set Property command sets a property in the device. The Set Property command number
is 1.
The Get and Set Property command data fields for the requests and responses are structured as
follows: