MagTek USB MagnePrint Swipe Reader with Encryption User Manual
Page 34
USB MagnePrint Swipe Reader with Encryption
26
Get Property Request Data:
Data Offset
Value
0 Property
ID
Get Property Response Data:
Data Offset
Value
0 – n
Property Value
Set Property Request Data:
Data Offset
Value
0 Property
ID
1 – n
Property Value
Set Property Response Data:
None
The result codes for the Get and Set Property commands can be any of the codes list in the
generic result code table.
Property ID is a one-byte field that contains a value that identifies the property. The following
table lists all the current property ID values:
Value
HID
mode
Value
KB
mode
Property ID
Description
0
0
SOFTWARE_ID
The device’s software identifier
1
1
SERIAL_NUM
The device’s serial number
2
2
POLLING_INTERVAL
The interrupt pipe’s polling interval
3
-
MAX_PACKET_SIZE
The interrupt pipe’s packet size
4
3
TRACK_ID_ENABLE
Track enable / ID enable
- 4
TRACK_DATA_SEND_FLAGS
Track data send flags
-
5
TERMINATION_CHAR
Terminating char / per track or card flag
-
6
SS_TK2_7BITS
Start sentinel char for track 2 – 7 bit data
-
7
Reserved for future use
-
8
SS_TK3_ISO_ABA
Start sentinel char for track 3 – ISO/ABA
-
9
SS_TK3_AAMVA
Start sentinel char for track 3 - AAMVA
-
10
SS_TK3_7BITS
Start sentinel char for track 3 – 7 bit data
- 11
PRE_CARD_CHAR
Pre
card
char
-
12
POST_CARD_CHAR
Post card char
- 13
PRE_TK_CHAR
Pre
track
char
-
14
POST_TK_CHAR
Post track char
- 15
ASCII_TO_KEYPRESS_CONV
ERSION_TYPE
Type of conversion performed when
converting ASCII data to key strokes
16
16
INTERFACE_TYPE
Type of USB interface
-
17
ACTIVE_KEYMAP
Selects which key map to uses
- 18
PRE_CARD_STRING
Pre
card
string
-
19
POST_CARD_STRING
Post card string
-
20
SS_TK1_ISO_ABA
Start sentinel char for track 1 – ISO/ABA
-
21
SS_TK2_ISO_ABA
Start sentinel char for track 2 – ISO/ABA
-
22
ES
End sentinel char for all tracks/formats
-
35
FS
Field Separator for additional data