1 setting the receiver identification number, 2 setting the communication rate – Videotec DTMRX2 User Manual
Page 37
![background image](/manuals/413445/37/background.png)
Page 11
MNVCDTMRX2_0351
7.1 Setting the receiver identification number
The receiver can be configured with an address between 1 and 99.
• make sure the power supply is disconnected (power supply LED off)
• configure the DIP switches of SW2 according to the following table :
DIP SWITCH
DIP SWITCH
DIP SWITCH
1234 567
1234 567
1234 567
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
+--- ---
-+-- ---
++-- ---
--+- ---
+-+- ---
-++- ---
+++- ---
---+ ---
+--+ ---
-+-+ ---
++-+ ---
--++ ---
+-++ ---
-+++ ---
++++ ---
---- +--
+--- +--
-+-- +--
++-- +--
--+- +--
+-+- +--
-++- +--
+++- +--
---+ +--
+--+ +--
-+-+ +--
++-+ +--
--++ +--
+-++ +--
-+++ +--
++++ +--
---- -+-
+--- -+-
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
-+-- -+-
++-- -+-
--+- -+-
+-+- -+-
-++- -+-
+++- -+-
---+ -+-
+--+ -+-
-+-+ -+-
++-+ -+-
--++ -+-
+-++ -+-
-+++ -+-
++++ -+-
---- ++-
+--- ++-
-+-- ++-
++-- ++-
--+- ++-
+-+- ++-
-++- ++-
+++- ++-
---+ ++-
+--+ ++-
-+-+ ++-
++-+ ++-
--++ ++-
+-++ ++-
-+++ ++-
++++ ++-
---- --+
+--- --+
-+-- --+
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
++-- --+
--+- --+
+-+- --+
-++- --+
+++- --+
---+ --+
+--+ --+
-+-+ --+
++-+ --+
--++ --+
+-++ --+
-+++ --+
++++ --+
---- +-+
+--- +-+
-+-- +-+
++-- +-+
--+- +-+
+-+- +-+
-++- +-+
+++- +-+
---+ +-+
+--+ +-+
-+-+ +-+
++-+ +-+
--++ +-+
+-++ +-+
-+++ +-+
++++ +-+
---- -++
+--- -++
-+-- -++
++-- -++
7.2 Setting the communication rate
The DTMRX2 (DTMRX224) receiver is able to carry out communications with four communication rates. Set
DIP switches 1 and 2 of SW1 according to the following table:
DIP 1
DIP 2
Baud
OFF
OFF
9600 *
OFF
ON
19200
ON
OFF
1200
ON
ON
38400
* Default setting