Siemens GS36NBI30 User Manual
Page 35
en
35
Fault
Possible cause
Remedial action
Freezer compartment door
was open for a long time;
temperature is no longer
reached.
The evaporator (refrigeration
generator) in the NoFrost
system is covered in thick ice
and can no
longer be defrosted fully
automatically.
To defrost the evaporator, remove the frozen
food with the compartments, insulate well
and store in a cool location.
Switch off the appliance and move it away
from the wall. Leave the appliance door open.
After approx. 20 min. the condensation begins
to run into the evaporation pan,
at the rear of the appliance. Fig. *
To prevent the evaporation pan
from overflowing in this case,
mop up the condensation with a sponge.
The evaporator is defrosted when the water
stops running into the evaporation pan. Clean
the interior. Switch the appliance
back on again.
Appliance is not cooling,
temperature display and light
are lit.
Showroom mode is
switched on.
Hold down alarm button, Fig 2/4, for
10 seconds until an acknowledgement signal
sounds.
After a short time check whether your
appliance is cooling.