beautypg.com

Appliance self-test, Starting the appliance self-test, Ending the appliance self-test – Siemens GS29NVW30 User Manual

Page 37: En 37

background image

en

37

Appliance self-test

Your appliance features an automatic

self-test program which shows you

sources of faults which may be repaired

by customer service only.

Starting the appliance self-test

1. Switch off the appliance and wait 5

minutes.

2. Switch on the appliance and hold

down the temperature selection

button, Fig. "/4, for 3-5 seconds

within the first 10 seconds until -26 °C

is lit on the temperature display.
The self-test programme starts, when

the temperature displays lit up

in succession.

When after a short time the appliance

displays the set temperature prior

to the self-test, everything is ok.

If the super display flashes for

10 seconds, an error has occurred.

Inform customer service.

Ending the appliance self-test

When the programme has ended, the

appliance switches over to normal

operation.

Fault

Possible cause

Remedial action

Freezer compartment door

was open for a long time;

temperature is no longer

reached.

The evaporator (refrigeration

generator) in the NoFrost

system is covered in thick ice

and can no

longer be defrosted fully

automatically.

To defrost the evaporator, remove the frozen

food with the compartments, insulate well

and store in a cool location.
Switch off the appliance and move it away

from the wall. Leave the appliance door open.
After approx. 20 min. the condensation begins

to run into the evaporation pan,

at the rear of the appliance. Fig. +
To prevent the evaporation pan

from overflowing in this case,

mop up the condensation with a sponge.
The evaporator is defrosted when the water

stops running into the evaporation pan. Clean

the interior. Switch the appliance

back on again.

This manual is related to the following products: