Hydraulic generator controller – hgc-2, Electrical system connections – High Country Tek HGC-2, Closed Loop Controller User Manual
Page 22
Hydraulic Generator Controller – HGC-2
22
HGC-2 Module Connection notes:-
1.
Ensure that the recommended fuses ( FS1 & FS2 ) is installed in the system for full protection and warranty.
2.
Use separate cables for each connection as shown above.
3.
Connect proportional valve coil cables and run separate from all/any high voltage wires.
4.
Ensure that high voltage feedback cable is protected to prevent insulation wear during usage through vibration
Electrical System Connections
:
Pin
Function
1
+VDC Input Supply
2
0VDC Input Supply
3
+Solenoid Connection O/P
4
-Solenoid Connection O/P
5
AC feedback Neutral I/P
6
AC feedback Line I/P
7
Constant Current Mode enable I/P
8
Controller ENABLE I/P
Beware of HIGH VOLTAGE when operating any
generator system
– high voltage can be LETHAL –
observe ALL laws, by-laws and health & Safety
recommendations for your immediate location,
state and/or country.