beautypg.com

Hydraulic generator controller – hgc-2, Electrical system connections – High Country Tek HGC-2, Closed Loop Controller User Manual

Page 22

background image

Hydraulic Generator Controller – HGC-2

22

HGC-2 Module Connection notes:-

1.

Ensure that the recommended fuses ( FS1 & FS2 ) is installed in the system for full protection and warranty.

2.

Use separate cables for each connection as shown above.

3.

Connect proportional valve coil cables and run separate from all/any high voltage wires.

4.

Ensure that high voltage feedback cable is protected to prevent insulation wear during usage through vibration

Electrical System Connections

:

Pin

Function

1

+VDC Input Supply

2

0VDC Input Supply

3

+Solenoid Connection O/P

4

-Solenoid Connection O/P

5

AC feedback Neutral I/P

6

AC feedback Line I/P

7

Constant Current Mode enable I/P

8

Controller ENABLE I/P

Beware of HIGH VOLTAGE when operating any

generator system

– high voltage can be LETHAL –

observe ALL laws, by-laws and health & Safety

recommendations for your immediate location,

state and/or country.