Hydraulic fan system controller: hfs – High Country Tek HFS User Manual
Page 13
Hydraulic Fan System Controller: HFS
The unit records the controller serial number, date first setup (born date) with a PC, highest supply voltage, the
highest temperature of each thermistor input (other than during calibration) and the highest module temperature. The
user can not reset these values without a password.
Shorted or open thermistor faults will not be recorded as a high temperature.
The facility exists to allow the user to „LOG‟ data of the thermistors and several other controller functions for later or
fault / trend examination.
The files can be individually named to suit the application and is suffixed with a *.csv extension for direct and easy
reading into Microsoft
®
Excel
®
for graphical plotting and mathematical calculations as required.
The connector used on this controller are DT15-12PA Deutsch 12 pin family and are of the two part, polarised, heavy
duty screw variety to suit the intended application environment while still allowing easy cable access, installation, pre-
looming and normal maintenance.
The controller comes with the integral male ( on the unit ) while the female is either customer supplied or can be
ordered from High Country Tek ( Part No.:- 999-10088 )
Connector:- Mating connector Parts:- ( Ordered separately )
Deutsch # DT06-12SA Plug
Deutsch # W12S – Lock
Deutsch # 0462-201-16141 – Socket pins
Deutsch distributor – Ladd Industrial sales – 1-800-223-1236.
The controller printed circuit board and components are sealed and impervious to hydraulic oils, other non corrosive
liquids and hostile environments.
If the controller is dirty, wipe clean with a cloth only. DO NOT use abrasive cleaners as this will degrade the units
information label.
If the controllers diagnostic indicator LED’s are broken, the unit will continue to function normally with no adverse
effects and will maintain the fully sealed rating.
The unit should be replaced as soon as possible if any of the LED indicators are damaged or broken to allow full local
diagnostic information on controller operation.
• E-Mail to :
• General Info
:
www.highcountrytek.com
Data Logging Option:
Internal Data Logging:
Connectors:
General Maintenance:
13