beautypg.com

Ec declaration of conformity – AMETEK 7100 Leak Detect Stik User Manual

Page 20

background image

18

EC Declaration of Conformity

Manufacturer:

AMETEK Automation & Process Technologies

6380 Brockway Road, Peck, MI 48466 USA

Identification of Equipment:

7100 Stik Series Liquid Level Transducer

Description of Device:

The device is a permanently mounted liquid level probe. It determines the level of a liquid based on

signal reflections, caused by magnetic floats, in a wire running the length of the probe. These signals are

amplified and processed, then relayed via a signal imposed on the input wires to the probe. The probe

body and tube may be constructed of stainless steel or of a flexible PVDF polymer. These devices also

take liquid level temperature measurements using thermistors located inside the probe tube.

EC type certificate:

DEMKO (0539)

09ATEX0902049X

Lyskaer 8, P.O. Box 514, 2730 Herlev, Denmark

Conformity Specifications: models 7100 M/R:

II 1 G Ex ia IIB T4 Ga Ta: -40ºC to +70ºC

models 7100 K/V:

II 1 G Ex ia IIA T4 Ga Ta: -40ºC to +70ºC

Council Directives:

Directive 94/9/EC, ATEX

Directive 89/336/EEC, EMC

Harmonized Standards:
EN60079-0:2012

Electrical apparatus for explosive gas atmospheres - Part 0:

General requirements

EN60079-11:2012

Electrical apparatus for explosive gas atmospheres - Part 11: Intrinsic

safety "i"

EN60079-26:2007

Explosive atmospheres – Part 26:

Construction, test and marking of group II category I G electrical

apparatus

EN61010-1:2010

Safety Requirements for Electrical Equipment for Measurement,

Control, and laboratory Use

Other Standards:

EN55011:1998

Limits and methods of measurement of radio characteristics of

industrial, scientific and medical (ISM) Radio Frequency equipment,

Class B, Group 1

EN50082-1:1992

Electromagnetic compatibility Generic immunity standard Part 1.

Residential, commercial and light industry

IEC 801-2:1984

ESD Susceptibility

IEC 801-3:1984

Radiated Susceptibility, Electromagnetic Field

IEC 801-4:1988

Conducted Susceptibility, Burst Interference Transients

Signed:

Name:

Glenn S. Loding

Dated: 10/25/13

Position: Engineering Manager Company: AMETEK Automation & Process Technologies