AMETEK 955DQ Brik LDT User Manual
Page 13

13
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.AMETEKAPT.com
TYPICAL SINGLE ENDED INTERFACE
N.C.
COMMON
VSOURCE
COMMON
B-
Z-
**
N.C.
**
A-
N.C.
**
Z+
Note:
**
B+
A+
COMMON
COMMON
VSOURCE
Z+
Z-
Note:
*
Rt *
B-
B+
A-
Rt
*
Rt
TYPICAL DIFFERENTIAL INTERFACE
A+
*
Rt is the termination resistor
typically used for RS-422 differential
connections. If these termination
resistors are not internal to the
controller, they should be installed
externally at the connector. If
these are not specified or included
with the controller, use 1K OHM
resistors.
Tie back and insulate unused
A-, B- and Z- wires.
955QD
LDT
955QD
LDT
Figure 3.4c Option H Output Connections for Differential Interface
POWER
SUPPLY
13.5 TO 30V
POWER
SUPPLY
13.5 TO 30V
Pin-5 BLUE
Pin-6 ORANGE
Pin-7 YELLOW
Pin-10 GRAY
Pin-3 GREEN
Pin-4 BROWN
Pin-2 RED
Pin-1 BLACK
Pin-5 BLUE
Pin-6 ORANGE
Pin-7 YELLOW
Pin-10 GRAY
Pin-3 GREEN
Pin-4 BROWN
Pin-2 RED
Pin-1 BLACK
Figure 3.4d Option H Output Connections for Single Ended Interface
CABLE ASSY
Part Number SD0527700LXX
X = Length in Feet
CABLE ASSY
Part Number SD0527700LXX
X = Length in Feet