COUNT MODE

Select the count mode that corresponds with your application. The input

actions are shown in the boxes below. For simple counting applications, it is
recommended to use Count with Direction for the count mode. Simply leave the
direction input unconnected.

















Counter A Subtract

Counter A Add

Counter A Add

Counter A Add

Quad A

Count A

Quad A

Count A

Quad A

Count A

Counter B Add

Counter A Add

Counter A Add

Rate only

Counter A Direction

Counter A

INPUT B ACTION

INPUT A ACTION



2 Input Add/Subtract



2 Input Add/Add



Quadrature x4



Quadrature x2



Quadrature x1



Dual Counter



Rate/Counter



Count with Direction

DISPLAY

MODE

Note: The Rate indicator signal is derived from Input A in all count modes.





MODULE MENU (PAR KEY)

Each module has a separate module menu (which is shown at the start of each

module discussion). The

PAR

key is pressed to advance to a particular parameter

to be changed, without changing the programming of preceding parameters.
After completing a module, the display will return to

 

. Programming

may continue by accessing additional modules.

SELECTION / VALUE ENTRY

For each parameter, the display alternates between the present parameter and

the selections/value for that parameter. The

SEL

and RST

keys are used to

move through the selections/values for that parameter. Pressing the

PAR

key,

stores and activates the displayed selection/value. This also advances the meter to
the next parameter.

For numeric values, the value is displayed with one digit flashing (initially the

right most digit). Pressing the

RST

key increments the digit by one or the user

can hold the

RST

key and the digit will automatically scroll. The

SEL

key

will select the next digit to the left. Pressing the

PAR

key will enter the value and

move to the next parameter.

PROGRAMMING MODE EXIT (PAR KEY)

The Programming Mode is exited by pressing the

PAR

key with



displayed. This will commit any stored parameter changes to memory and return
the meter to the Display Mode. (If power loss occurs before returning to the
Display Mode, verify recent parameter changes.)

PROGRAMMING TIPS

It is recommended to start with Module 1 for counting or Module 2 for rate.

When programming is complete, it is recommended to record the parameter
programming and lock out parameter programming with the user input or
programming security code.

FACTORY SETTINGS

Factory Settings may be completely restored in Module 3. This is useful when

encountering programming problems.

ALTERNATING SELECTION DISPLAY

In the explanation of the modules, the following dual display with arrows will

appear. This is used to illustrate the display alternating between the parameter
on top and the parameter’s Factory Setting on the bottom. In most cases,
selections and values for the parameter will be listed on the right.

Indicates Program Mode Alternating Display

Factory Settings are shown.





Parameter

Selection/Value

PAR

Dual Count or Batch

Only

Counter B

Scale Factor

Counter A

Reset Action

Counter A

Decimal Point

Count

Mode

Counter B

Decimal Point

Counter A

Scale Factor

Dual Count or

Batch Only

Counter B

Batch Count

Enable

Counter A

Count Direction

Counter Reset

at Power-up

User Input

Function

User Input

Assignment

Counter A

Count Load

Value

1-INP

Pro

b-ScF

A-rSt

A-Scf

INP Ab

A-dPt

b-dPt

b-bAt

Cnt Ld

A-dir

USrINP

r P-UP

USrASN

5.1 MODULE 1 - I

NPUT

S

ETUP

P

ARAMETERS

(



)

PARAMETER MENU

Shaded area selections only apply when Counter B is enabled (Dual Count

mode or batch counter).

COUNTER A DECIMAL POINT POSITION

This selects the decimal point position for Counter A and the setpoint value,

if assigned to Counter A. The selection will also affect Counter A scale
factor calculations.











COUNTER A SCALE FACTOR

The number of input counts is multiplied by the scale factor to obtain the

desired process value. A scale factor of 1.0000 will result in the display of the
actual number of input counts. (Details on scaling calculations are explained at
the end of this section.)*



to







COUNTER A RESET ACTION





When Counter A is reset, it returns to Zero or Counter A Count Load value.

This reset action applies to all Counter A resets, except a Setpoint generated
Counter Auto Reset programmed in Module 4.





COUNTER A COUNT DIRECTION





Reverse (



) switches the normal Counter A count direction shown in the

Count Mode parameter chart.



