The



selection allows the

SEL

key to toggle through the enabled

displays.

FRONT PANEL DISPLAY SELECT ENABLE (SEL

)

The



selection allows the

RST

key to reset the selected counter(s). The

shaded selections are only active when Counter B is enabled (Dual Count Mode
or batch counter).

FRONT PANEL COUNTER RESET ENABLE (RST

)

The



selection allows the display to automatically scroll through the

enabled displays. The scroll rate is about every 4 seconds.

DISPLAY SCROLL ENABLE

Enter the desired Display Intensity Level (1-5). The display will actively dim

or brighten as levels are changed.

DISPLAY INTENSITY LEVEL

The Security Code determines the programming mode and the accessibility

of programming parameters. This code can be used along with the Program
Mode Lock-out (



) in the User Input Function parameter (Module 1).

Two programming modes are available. Full Programming mode allows all

unit parameters to be viewed and modified. Quick Programming mode permits
only user selected values to be modified, but allows direct access to these values
without having to enter Full Programming mode.

Entering a Security Code from 1-99 enables Quick Programming mode, and

displays a sublist to select which values appear in the Quick Programming
menu. All of the values set to



in the sublist are accessible in Quick

Programming. The values include Setpoints (



,



), Output Time-outs

(



,



), Count Load value (



) and Display Intensity (



).

Programming any Security Code other than 0, requires this code to be entered

at the



prompt in order to access Full Programming mode. Quick

Programming mode, if enabled, is accessed before the



prompt appears.

PROGRAMMING SECURITY CODE






















to





to





















USER INPUT

FUNCTION

USER INPUT

STATE

SECURITY

CODE

MODE WHEN “PAR”

KEY IS PRESSED

FULL PROGRAMMING

MODE ACCESS

0

Full Programming

Immediate Access

not



______

1-99

Quick

Programming

After Quick Programming

with correct code entry

at



prompt *

100-999



prompt

With correct code entry

at



prompt *

0

Programming Lock

No Access

Active

1-99

Quick

Programming

No Access



100-999



prompt

With correct code entry

at



prompt *

Not Active

0-999

Full Programming

Immediate Access

* Entering Code 222 allows access regardless of security code.

INPUT FREQUENCY CALCULATION

The meter determines the input frequency by summing the number of falling

edges received during a sample period of time. The sample period begins on the
first falling edge. At this falling edge, the meter starts accumulating time
towards Low Update and High Update values. Also, the meter starts
accumulating the number of falling edges. When the time reaches the Low
Update Time value, the meter looks for one more falling edge to end the sample
period. If a falling edge occurs (before the High Update Time value is reached),
the Rate display will update to the new value and the next sample period will
start on the same edge. If the High Update Time value is reached (without
receiving a falling edge after reaching Low Update Time), then the sample
period will end but the Rate display will be forced to zero. The High Update
Time value must be greater than the Low Update Time value. Both values must
be greater than 0.0. The input frequency calculated during the sample period, is
then shown as a Rate value determined by the scaling calculation.

5.3 MODULE 3 - D

ISPLAY

AND

F

RONT

P

ANEL

K

EY

P

ARAMETERS

(



)

PAR

Pro

Front Panel

Counter

Reset Enable

Front Panel

Display Select

Enable

Display

Scroll

Enable

Factory

Service

Operations

Programming

Security

Code

Display

Intensity

Level

3-dSP

SEL-En

rSt-En

ScroLL

d-LEV

CodE

FCS

PARAMETER MENU