Nstalling, Eter, Ordering information – Red Lion LD User Manual
Page 2
2
ORDERING INFORMATION
TYPE
MODEL NO.
DESCRIPTION
PART NUMBER
Basic
(No front
panel keys)
LD
2.25" High 4-Digit Red LED Counter
LD200400
2.25" High 6-Digit Red LED Counter
LD200600
4" High 4-Digit Red LED Counter
LD400400
4" High 6-Digit Red LED Counter
LD400600
Programmable
(With front
panel keys)
LD
2.25" High 6-Digit Red LED Count/Rate Indicator w/ dual Relay Output &
RS232/RS485 Serial Communications
LD2006P0
4" High 6-Digit Red LED Count/Rate Indicator w/ dual Relay Output & RS232/
RS485 Serial Communications
LD4006P0
LD Plug
Panel Meter Plug for LD models
LDPLUG00
5. RESET/USER INPUT: Function programmable for LD2006P0 &LD4006P0
Reset/User Input: DIP switch selectable pull-up (7.8 K
) or pull-down
resistor (3.9 K
) that determines active high or active low input logic.
Trigger levels: V
IL
= 1.0 V max; V
IH
= 2.4 V min; V
MAX
= 28 VDC
Response Time: 10 msec typ.; 50 msec debounce (activation and release)
6. COMMUNICATIONS (LD2006P0 & LD4006P0 only):
RS485 SERIAL COMMUNICATIONS
Type: RS485 multi-point balanced interface (isolated)
Baud Rate: 300 to 38.4 k
Data Format: 7/8 bits; odd, even, or no parity
Bus Address: 0 to 99; max 32 meters per line
RS232 SERIAL COMMUNICATIONS
Type: RS232 half duplex (isolated)
Baud Rate: 300 to 38.4 k
Data Format: 7/8 bits; odd, even, or no parity
7. MEMORY: Nonvolatile E
2
PROM retains all programming parameters and
count values when power is removed.
8. OUTPUT (LD2006P0 & LD4006P0 only):
Type: Dual Form C contacts
Contact Rating: 5 amps @ 120/240 VAC or 28 VDC (resistive load), 1/8
H.P. @ 120 VAC (inductive load)
Life Expectancy: 100 K cycles min. at full load rating. External RC snubber
extends relay life for operation with inductive loads.
Response Time: Turn On or Off: 5 msec max.
Isolation to Input & User/Exc Commons: 2000 Vrms for 1 min.
Working Voltage: 240 Vrms
9. ENVIRONMENTAL CONDITIONS:
Operating temperature: 0 to 65 °C
Storage temperature: -40 to 70 °C
Operating and storage humidity: 0 to 85% max. RH (non-condensing)
Vibration According to IEC 68-2-6: Operational 5 to 150 Hz, in X, Y, Z
direction for 1.5 hours, 2 g’s (1g relay).
Shock According to IEC 68-2-27: Operational 30 g’s (10g relay), 11 msec in
3 directions.
Altitude: Up to 2,000 meters
10. CONNECTIONS:
Internal removable terminal blocks are used for power and signal wiring.
Remove end plates with ¼" nut driver. For LD4 versions, all wiring is on right
side of unit. For LD2 versions, power and signal wiring connections are on
the right side and the relays and serial options are on the left side.
Wire Strip Length: 0.4" (10 mm)
Wire Gage: 24-12 AWG copper wire, 90°C rated insulation only
Torque: 5.3 inch-lbs (0.6 N-m) max.
Cable Diameter: Outside diameter must be 0.181" (4.6 mm) to 0.312" (7.9
mm) to maintain NEMA 4 rating of cord grips.
11. CERTIFICATIONS AND COMPLIANCES:
SAFETY
UL Listed, File # E137808, UL508, CSA C22.2 No. 14-M95
LISTED by Und. Lab. Inc. to U.S. and Canadian safety standards
Type 4X Enclosure rating, UL50
IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment for
measurement, control, and laboratory use, Part 1.
IP65 Enclosure rating, IEC 529
ELECTROMAGNETIC COMPATIBILITY
Emissions and Immunity to EN 61326: Electrical Equipment for Measurement,
Control and Laboratory use.
Notes:
1. Criterion A: Normal operation within specified limits.
2. Criterion B: Temporary loss of performance from which the unit self-
recovers.
12. CONSTRUCTION: Aluminum enclosure, and steel side panels with textured
black polyurethane paint for scratch and corrosion resistance protection. Meets
NEMA 4X/IP65 specifications. Installation Category II, Pollution Degree 2.
13. WEIGHT:
LD2004XX: 3.5 lbs (1.59 kg)
LD2006XX: 4.5 lbs (2.04 kg)
LD4004XX: 8 lbs (3.63 kg)
LD4006XX: 10.5 lbs (4.76 kg)
Class A
Class B
EN 55011
EN 55011
Emissions LD2006P0
Emissions LD200400
Emissions:
0.5 cycle
Criterion A
3 V/rms
EN 61000-4-11
Voltage dip/interruptions
Criterion A
EN 61000-4-6
RF conducted interference
1 kV L-L,
Criterion A
EN 61000-4-5
Surge
1 kV signal
2 kV power
Criterion A
EN 61000-4-4
Fast transients (burst)
2 kV L&N-E power
10 V/m
Criterion B LD2006P0
Criterion A LD200400
EN 61000-4-3
Electromagnetic RF fields
8 kV air discharge
4 kV contact discharge
Criterion A
EN 61000-4-2
Electrostatic discharge
Immunity to Industrial Locations:
1.0 I
NSTALLING
THE
M
ETER
INSTALLATION
The meter meets NEMA 4X/IP65 requirements when properly installed.
INSTALLATION ENVIRONMENT
The unit should be installed in a location that does not exceed the operating
temperature. Placing the unit near devices that generate excessive heat should
be avoided. The unit should only be cleaned with a soft cloth and neutral soap
product. Do NOT use solvents.
Continuous exposure to direct sunlight may accelerate the aging process of
the front overlay. Do not use tools of any kind (screwdrivers, pens, pencils, etc.)
to operate the keypad of the unit.
MOUNTING INSTRUCTIONS
This display is designed to
be wall mounted or suspended
from a ceiling truss or other
suitable structure capable
of supporting the LD.
Caution should be exercised
when hanging the display to
provide for the safety of
personnel. If hanging the LD,
run the suspension cables (or
chains) through the mounting
bracket holes. For wall mounting
use #10-32 size bolts.
MOUNTING HOLE (.281")
MUST BE
CONNECTED TO
TERMINAL #3 (TBA)