Technical Notes

Battery Charge Factor (BCF)

Some energy is lost both when recharging and discharging a battery. The FLEXnet DC

compensates for these losses by discounting the amp-hours charging the battery, meaning

it doesn’t count every hour used for recharging as actually recharging. Some of them are lost

due to heat and gassing. The FLEXnet DC’s default BCF is 94, which means for every 100 amp

hours of charge to the battery, only 94 are shown in the amp hour display for a BCF of 94%.

This means 6% of the amp hours is lost.

As the system goes through a few recharging cycles, the range of state-of-charge (SOC)

percentages will vary, but should fall into a predictable range. This allows the user to change

the BCF if necessary for more effi

cient recharging. If the SOC displays as full before the battery

charge settings are met (either before the time setting or amp hour setting is satisfi ed), the

BCF should be lowered because it’s assuming too many amp hours have been recharging the

battery. By lowering the BCF, the FLEXnet DC will read more hours as being unused due to

ineffi

ciency.