Checking Error Code Chart
Incorrect wiring or disconnected Airflow Signal 1
Airflow Signal 1
input error
Airflow voltage
output error
No Injector
pulse from all
No Injector 1 pulse
No Injector 2 pulse
No Injector 3 pulse
No Injector 4 pulse
Incorrect Airflow signal output wiring.
Not receiving an injector signal for
Additional Injection Map
Not receiving injector signal I/J CH-1
for Additional Injection Map
Not receiving injector signal I/J CH-2
for Additional Injection Map
Not receiving injector signal I/J CH-3
for Additional Injection Map
Not receiving injector signal I/J CH-4
for Additional Injection Map
CODE
11
15
20
21
22
23
24
31
32
33
34
40
41
42
43
44
49
51
52
53
54
57
Improper order of
Ignition input signal
Error
Error description
Incorrect Injector 1
pulse
Incorrect Injector 2
pulse
Incorrect Injector 3
pulse
Incorrect Injector 4
pulse
Incorrect wiring order of the ignition signal wires.
Incorrect I/J CH-1 wire to e-Manage unit
Incorrect I/J CH-2 wire to e-Manage unit
Incorrect I/J CH-3 wire to e-Manage unit
Incorrect I/J CH-4 wire to e-Manage unit
No Ignition Signal 1
pulse
No Ignition Signal 2
pulse
No Ignition Signal 3
pulse
No Ignition Signal 4
pulse
Not receiving the ignition signal to IG CH-1
Not receiving the ignition signal to IG CH-2
Not receiving the ignition signal to IG CH-3
Not receiving the ignition signal to IG CH-4
Incorrect Ignition 1
pulse
Incorrect Ignition 2
pulse
Incorrect Ignition 3
pulse
Incorrect Ignition 4
pulse
No Ignition pulse
JP2 + 12V
error
Incorrect IG CH-1 wire to e-Manage unit
Incorrect IG CH-2 wire to e-Manage unit
Incorrect IG CH-3 wire to e-Manage unit
Incorrect IG CH-4 wire to e-Manage unit
Incorrect Jumper setting (JP2)
Not receiving the ignition signal
to any of the channels