beautypg.com

Checking error code chart – GReddy TURBO KITS: Nissan 240SX 1995-98 / TD06-20G User Manual

Page 18

background image

Checking Error Code Chart












Incorrect wiring or disconnected Airflow Signal 1

Airflow Signal 1
input error

Airflow voltage
output error
No Injector
pulse from all

No Injector 1 pulse

No Injector 2 pulse

No Injector 3 pulse

No Injector 4 pulse

Incorrect Airflow signal output wiring.

Not receiving an injector signal for
Additional Injection Map

Not receiving injector signal I/J CH-1
for Additional Injection Map

Not receiving injector signal I/J CH-2
for Additional Injection Map

Not receiving injector signal I/J CH-3
for Additional Injection Map

Not receiving injector signal I/J CH-4
for Additional Injection Map

CODE

11

15

20

21

22

23

24

31

32

33

34

40

41

42

43

44

49

51

52

53

54

57

Improper order of
Ignition input signal

Error

Error description

Incorrect Injector 1
pulse

Incorrect Injector 2
pulse
Incorrect Injector 3
pulse

Incorrect Injector 4
pulse

Incorrect wiring order of the ignition signal wires.

Incorrect I/J CH-1 wire to e-Manage unit

Incorrect I/J CH-2 wire to e-Manage unit

Incorrect I/J CH-3 wire to e-Manage unit

Incorrect I/J CH-4 wire to e-Manage unit

No Ignition Signal 1
pulse

No Ignition Signal 2
pulse
No Ignition Signal 3
pulse
No Ignition Signal 4
pulse

Not receiving the ignition signal to IG CH-1

Not receiving the ignition signal to IG CH-2

Not receiving the ignition signal to IG CH-3

Not receiving the ignition signal to IG CH-4

Incorrect Ignition 1
pulse

Incorrect Ignition 2
pulse
Incorrect Ignition 3
pulse

Incorrect Ignition 4
pulse

No Ignition pulse

JP2 + 12V
error

Incorrect IG CH-1 wire to e-Manage unit

Incorrect IG CH-2 wire to e-Manage unit

Incorrect IG CH-3 wire to e-Manage unit

Incorrect IG CH-4 wire to e-Manage unit

Incorrect Jumper setting (JP2)

Not receiving the ignition signal
to any of the channels