Ensure error-free transmission, Save the setup, Exit hyperterminal – DAVIS DriveRight Remote Download Kit Manual (8188) User Manual
Page 7: Test the field modem, Executing a download
5
3. Ensure error-free transmission.
To configure the modem to use a standard error detection pro-
tocol, type
A T & M 4
and press Enter.
4. Save the setup.
To save the setup in non-volatile memory so it will load when
the modem is turned on, type
A T & W
and press Enter.
NOTE:
If you are NOT using the US Robotics Courier V. Everything, set
the field modem to operate in quiet mode. Quiet mode ensures that
the DriveRight unit does not interpret chance modem responses as
commands. Type
A T E Q 1 W
and press Enter. You will not receive an OK after this command
(nor would you see your commands echoed in the HyperTerminal
window if you continued to enter them) because the modem is in
quiet mode.
5. Exit HyperTerminal.
6. Test the field modem.
To test the field modem, execute a download. It may be help-
ful, for this first download, to have the field modem and host
computer in the same room so you can see both at once - in
which case, you need two separate phone lines. However, if
two lines are not possible, simply execute a download “from
the field” as a driver would.
See the following section for instructions on executing a down-
load. If the download fails, see the troubleshooters on page 7.
Executing a Download
Executing a download is quite simple once the field modem is pre-
programmed, but it does require some actions both on the host com-
puter and in the field.
Remote Dowload Manual D006.fm Page 5 Thursday, April 17, 2003 8:08 AM