Turbo Action 70600 CHEETAH E-SHIFT Controller User Manual
Page 5
5
Figure #1
CHEETAH E-SHIFT Controller
#70600
NOTE:
The terminal block containing the 1-4 shift outputs also has one input which
can be 12-16 Volts (The preferred way to wire up shift devices.) or a ground
(
Dangerous way to wire shift devices.
) depending on the device you are trying to
activate. This power source passes directly to the outputs when the controller
activates the appropriate relay or relays. We suggest 12-16V power be supplied
to the device from your CHEETAH E-SHIFT Controller and have your solenoid or
light grounded at its location. Note: Some Electric Shifters such as Dedenbear,
Biondo, Etc. require a high current relay Turbo Action Part #5000-1. See Fig. #4.
Shift Lights
Digital Display
1000’s Set 100’s Set
Time Select Time Set
Function
Switch
Reset
Switch
Terminal Block
Inputs
Terminal Block
Outputs/Input
6 5 0 0
12-16V
Ground
T
ach Input
Burnout/linelock
Pit Road
T
ranz Brake/Clutch
4th Shift Out
3rd Shift Out
2nd Shift Out
1st Shift Out
12-16V Input
(See note below)
1
2
3
4
5 6
5
4
3
2
1
9/19/14
12-16V must be connected
to battery, no switch in
between!
Ground must be connected
to same location that the
car ignition gets its ground!