Alliance Laundry Systems HC18PC2 User Manual
Page 14

Operation
F232137
12
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Display Indications for V-Series – Non-Coin
Display
Meaning
Display
Meaning
FP 1
Program identification code (ROM)
(this is an example only)
n
Ed
Medium water level
HI
High water level
HoLd
Wait...power has just been turned on
SUP1
Supply 1
CY
Cycle (followed by two-digit number)
SUP2
Supply 2
tESt/CYC*
Test cycle selected
SUP3
Supply 3
FAr
Degrees Fahrenheit
SUP4
Supply 4
CEL
Degrees Celsius
SUP5
Supply 5 (Setup option)
HEAt
Auxiliary heat enabled
SUP6
Supply 6 (supply 1 and 5)
noHt
Auxiliary heat disabled
SUP7
Supply 7 (supply 3 and 4)
tFIL
Temperature-controlled fill enabled
SLo/For
Gentle wash speed, forward direction
ntFL
Temperature-controlled fill disabled
SLo/rEv
Gentle wash speed, reverse direction
CooL
Automatic cool-down enabled
nor
n
/For
Normal wash speed, forward direction
noCL
Automatic cool-down disabled
nor
n
/rEv
Normal wash speed, reverse direction
Ag 1
Agitation 1 selected (90% agitation)
drAI
Drain enabled
Ag 2
Agitation 2 selected (33% agitation)
nodr
Drain disabled
Ag 3
Agitation 3 selected (10% agitation)
dISt
Distribution (load balancing before extract)
Ag 4
Agitation 4 selected (6.7% agitation)
SPIn/tI
n
E*
Reads “SPIn” for one second, then
“tI
n
E” followed by time for spin
AgSn
Agitation speed normal
AgSL
Agitation speed low
SPn1
Lowest of three spins
PU
n
P
Pump output enabled (future use only)
SPn2
Middle of three spins
nP
n
P
Pump output disabled (future use only)
SPn3
Highest of three spins
PrE
Prewash segment (1st of 11 segments)
STOP
Stop routine
UASH
Wash segment (2nd of 11 segments)
SdLY
Spin coast delay
FIL1
First fill (3rd of 11 segments)
dOnE
Cycle and stop routine have ended
FIL2
Second fill (4th of 11 segments)
dFLt
Drive fault detected
FIL3
Third fill (5th of 11 segments)
dOOr
Door not properly closed
FIL4
Fourth fill (6th of 11 segments)
bAL/FAIL*
Balancing routine failed during test cycle
after 10 attempts to balance load
FIL5
Fifth fill (7th of 11 segments)
FIL6
Sixth fill (8th of 11 segments)
FILL/STOP*
Programmed water level not reached after 30
minutes
FIL7
Seventh fill (9th of 11 segments)
FIL8
Eighth fill (10th of 11 segments)
FULL
The computer detects low water level or
higher when none should be present
FIL9
Ninth fill (11th of 11 segments)
CFIL
Cold fill
rotA
Computer detects possible rotation of motor
when there should be none
bFIL
Warm fill (both hot and cold)
HFIL
Hot fill
tSFL
Temperature sensor failure or temperature
out of range
AFIL
Auxiliary fill (Setup option)
Lo
Low water level
* Display indications separated by a slash (/) represent a flashing display.
Table 4