Display Indications for V-Series – Coin

Display

Meaning

Display

Meaning

FC 5

Program identification code (ROM)
(this is an example only)

HFIL

Hot fill

Lo

Low water level

HoLd

Wait...power has just been turned on

n

Ed

Medium water level

PAY/(price)*

Pay (flashes alternately with start price if
“FLSH” SETUP option is enabled)

HI

High water level

SUP0

No supplies

CYXX

Cycle (followed by two-digit number)

SUP1

Supply 1

tESt/CYC*

Test cycle selected

SUP2

Supply 2

FAr

Degrees Fahrenheit

SUP3

Supply 3

CEL

Degrees Celsius

SUP5

Supply 5 (supply 1 and 2)

HEAt

Auxiliary heat enabled

SUP6

Supply 6 (supply 2 and 3)

noHt

Auxiliary heat disabled

drAI/dISt*

Distribution (load balancing before extract)
(Variable-speed only)

drAI/For*

Drain step (low speed forward in test cycle)

Strt/A

n

t*

Start amount – flashes briefly before
showing vend price in SETUP Mode

SPIn/tI

n

E*

Reads “SPIn” for one second, then “tI

n

E”

followed by time for spin

SdLY

Spin coast delay

Con1/deno*

Coin 1 value – flashes briefly before
showing value of coin 1 in SETUP Mode

STOP

Stop routine

donE

Cycle and stop routine have ended

Con2/deno*

Coin 2 value – flashes briefly before
showing value of coin 2 in SETUP Mode

HI 1

Low spin in test cycle (Variable-speed only)

HI 2

High spin in test cycle (Variable-speed only)

PrE

Prewash segment (1st of 8 segments)

bAL/FAIL*

Balance routine failed during test cycle

UASH

Wash segment (2nd of 8 segments)

SHUT/door*

Door not properly closed

FIL1

First fill (3rd of 8 segments)

CANt/OPEN*

Computer cannot unlock door after five
attempts

FIL2

Second fill (4th of 8 segments)

FIL3

Third fill (5th of 8 segments)

FILL/STOP*

Programmed water level not reached after
30 minutes

FIL4

Fourth fill (6th of 8 segments)

FIL5

Fifth fill (7th of 8 segments)

FULL

The computer detects low water level or
higher when none should be present

FIL6

Sixth fill (8th of 8 segments)

AFIL

Auxiliary fill

dFLt

Drive fault detected (Variable-speed only)

bFIL

Warm fill (both hot and cold)

tSFL

Temperature sensor failure or temperature
out of range

CFIL

Cold fill

bLCH

Add bleach (for supply 2 only)

bAL?

Special factory balance SETUP Mode

1Pr

One vend price – all cycles

SPC?

Special factory Valve Flush Mode

16Pr

16 vend prices – one per cycle

SPIN

Spin in test cycle (2 speed only)

CHEC/CYC*

Test cycle selected (same as tESt/CYC)

rEv

Reverse wash speed in test cycle

For

Wash speed forward in test cycle

FrEE

“Free” cycle option

* Display indications separated by a slash (/) represent an alternating display.