H

YDRAULIC

S

YSTEM

Standard Two-Circuit Hydraulic Plumbing

The apron cylinders and the push-off cylinder are controlled on the same circuit with

the sequence of the operation controlled by a sequence valve. The other hydraulic

circuit controls the lift cylinders on the earthmover.

*To adjust the sequence valve, see Troubleshooting section.

Optional Three-Circuit Hydraulic Plumbing

The apron cylinders, push-off cylinder, and lift cylinders are all on separate hydraulic

circuits.

P

USHING THE

E

ARTHMOVER

The I-130XL was designed to be pushed when equipped with the optional push-bar. How-

ever, Ashland Industries, Inc. STRONGLY recommends using extreme caution when push-

ing the I-130XL earthmover to prevent any unnecessary damage.

CAUTION! The I-130XL earthmover must be pushed in a straight line with a

maximum of a 100 hp dozer. Do not ram or jar the earthmover while

pushing and push at a constant speed.