beautypg.com

HP ProLiant DL385 G6 Server User Manual

Page 90

background image

Specifications 90

HP ProLiant 750 W Power Supply

Specification Value

Input requirements

Rated input voltage

100V to 120V AC
200V to 240V AC

Rated input frequency

50Hz to 60Hz

Rated input current

8.9A at 100V AC
4.3A at 200V AC

Rated input power

857 W at 100V AC input
824 W at 200V AC input

BTUs per hour

2925 at 100V AC input
2812 at 200V AC input

Power supply output

Rated steady-state power

750 W at 100V to 120V AC
input
750 W at 200V to 240V AC
input

Rated peak power

750 W at 100V to 120V AC
input
750 W at 200V to 240V AC
input

HP ProLiant 1200 W Power Supply

Specification Value

Input requirements

Rated input voltage

100V to 120V AC
200V to 240V AC

Rated input frequency

50 Hz to 60 Hz

Rated input current

10A at 100V AC
4.9A at 200V AC

Rated input power

930 W at 100V AC input
1348 W at 200V AC input

BTUs per hour

3530 at 120V AC input
4600 at 200V to 240V AC
input

Power supply output

Rated steady-state power

800 W at 100V AC input
900 W at 120V AC input
1200 W at 200V to 240V AC
input