Changing the USB version support

The factory default setting for this server is USB version 1.1. After the OS has loaded, this setting can be

changed to USB version 2.0 using the following steps:

1.

Access RBSU by pressing F9 during power up.

2.

Select System Options.

3.

Select USB External Port Capability.

4.

Press Enter to display USB 1.1 and USB 2.0 selections.

5.

Arrow down to highlight USB 2.0.

6.

Press Enter.

7.

Press F10 to save the change and exit RBSU.

Internal USB functionality

An internal USB connector is available for use with USB drive keys only. This solution provides for use of

a permanent boot drive from a USB drive key installed in the internal connector, avoiding issues of

clearance on the front of the rack and physical access to secure data.
For additional security, the external USB connectors can be disabled through RBSU. Disabling external

USB in RBSU disables the front USB connector and both rear USB connectors.

Diagnostic tools

Survey Utility

Survey Utility, a feature within HP Insight Diagnostics (on page

73

), gathers critical hardware and

software information on ProLiant servers.
This utility supports operating systems that may not be supported by the server. For operating systems

supported by the server, refer to the HP website (

http://www.hp.com/go/supportos

).

If a significant change occurs between data-gathering intervals, the Survey Utility marks the previous

information and overwrites the Survey text files to reflect the latest changes in the configuration.
Survey Utility is installed with every SmartStart-assisted installation or can be installed through the HP PSP

("

ProLiant Support Packs

" on page

74

).

NOTE: The current version of SmartStart provides the memory spare part numbers for the server. To

download the latest version, see the HP website (

http://www.hp.com/go/ssdownloads

).

Array Diagnostic Utility

ADU is a tool that collects information about array controllers and generates a list of detected problems.

ADU can be accessed from the SmartStart CD ("

SmartStart software

" on page

65

) or downloaded from

the HP website (

http://www.hp.com

).