Remove the access panel, Install the access panel, Remove and install the air baffle – HP ProLiant DL365 Server User Manual
Page 20: 20 remove and install the air baffle

Operations 20
WARNING: To reduce the risk of personal injury, be careful when pressing the server
rail-release latches and sliding the server into the rack. The sliding rails could pinch your
fingers.
5.
After performing the installation or maintenance procedure, slide the server into the rack:
a.
Slide the server fully into the rack.
b.
Secure the server by tightening the thumbscrews.
6.
Connect the peripheral cables and power cords.
Remove the access panel
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and
the internal system components to cool before touching them.
CAUTION: Do not operate the server for long periods with the access panel open or removed. Operating
the server in this manner results in improper airflow and improper cooling that can lead to thermal damage.
1.
Power down the server if the standard cable management solution is installed ("
NOTE: If the optional cable management arm is installed, you can extend the server and perform hot-plug
installation or maintenance procedures without powering down the server.
2.
Extend or remove the server from the rack ("
Extend the server from the rack
3.
Lift up on the hood latch handle and remove the access panel.
Install the access panel
1.
Place the access panel on top of the server with the hood latch open. Allow the panel to extend past
the rear of the server approximately 0.8 cm (0.2 in).
2.
Engage the anchoring pin with the corresponding hole in the latch.
3.
Push down on the hood latch. The access panel slides to a closed position.
Remove and install the air baffle
1.
Power down the server (on page
2.
Extend or remove the server from the rack ("
Extend the server from the rack
3.
Remove the access panel (on page