Intrac-305 installation – Advantech INTRAC-305 User Manual
Page 81

INTRAC-305
INSTALLATION
© 2011 Advantech Wireless
INTRAC-305 MANUAL - Issue 3.2
Page 69
6
Motor Control
The INTRAC-305 outputs low voltage low current motor drive
signals to the Motor Drive Cabinet.
INTRAC
TM
305 Motor Controls Connector
50 Way
D type
Socket
Signal Name
(SimAx)
18
+12v
1
East * (Northern Hemisphere)
19
+12v
2
West * (Northern Hemisphere)
20
+12v
3
Fast Az
21
+12v
4
Slow Az
22
+12v
5
Down
23
+12v
6
Up
24
+12v
7
Fast El
25
+12v
8
Slow El
26
+12v
9
Pol CCW
27
+12v
10
PolCW
*
In the Southern Hemisphere drive direction is reversed.
Note
All other pins of the 50 way connector are unused.