Figure 81 Detailed Information Window

The Detailed Information window shows the following:

Status: The status of the pair. If the pair is split (or suspended), Status also shows the suspend
type. If the pair is waiting for initial copy, Status also shows the word (Queuing). If the XP
Continuous Access Journal pair for delta resync operation in the 3DC multi-target configuration
that consists of three XP Continuous Access Journal sites is displayed, the P icon (primary data
volume) should be deemed to be replaced with the S icon (secondary volume). In this case,
both volumes of the pair mean the secondary volume. The direction of the copy operation

Displaying Detailed Information about a Pair of Data Volumes