background image

Table 3 REQUEST operation errors

Corrective action

Description

Error

N/A

Normal

noError (0)

Verify that the name of the requested
object is correct.

noSuchName (2)

There are no MIB objects that are required. (Not
supported.)

The GETNEXT REQUEST command that is specified
for the following object identifier of the last supported
MIB object is received.

SET operation is not supported.

SET REQUEST is received.

readOnly (4)

Retry the operation.

Error occurred for other reasons.

genErr (5)

Component status information from SNMP Manager

You can obtain the status information of certain storage system components from the SNMP
Manager. The following table lists the components for which the status can be obtained.

Table 4 Storage system components

Component name

Area

Processor(s)

Storage System

BUS

Cache

Shared memory

Power supplies

Batteries

Fans

Others

Power supplies

Disk Unit

Fans

Hard disks

Others

The following table lists the status of storage system components, as well as the trap report functions.

Table 5 Storage system component status

Description

Status

Normal operation.

Normal

All operations in a storage system stopped.

Acute failure detected

Operation in a component where a failure occurred stopped.

Serious failure detected

Partial failure.

Moderate failure detected

Minor failure.

Service failure detected

8