background image

Table 14 SNMP failure trap reference codes (continued)

Alert level

Description

Trap reference code

SIM13

SIM23

SIM22

MODERATE

Processor

DMA block

xy

83

CF

MODERATE

Processor

Synchronized DMA block

xx

87

CF

MODERATE

Processor

LR block

xx

88

CF

MODERATE

Processor

All DMA block

xx

89

CF

MODERATE

Processor

MF DMA block

xx

Bx

CF

MODERATE

Processor

All MF DMA block

xx

C0

CF

SERIOUS

Failure with paired
volumes

Pair suspend due to RIO path block

xx

0x

D4

SERIOUS

Failure with paired
volumes

Pair suspend due to failure detected in M-VOL

xx

1x

D4

SERIOUS

Failure with paired
volumes

Pair suspend due to failure detected in R-VOL

xx

2x

D4

SERIOUS

Failure with paired
volumes

Pair suspend due to DFW/DRV CAC off from
R-VOL

xx

3x

D4

SERIOUS

Failure with paired
volumes

Pair suspend due to the suspend report from
R-VOL

xx

4x

D4

SERIOUS

Failure with paired
volumes

Pair suspend due to the Simplex report from
R-VOL

xx

5x

D4

SERIOUS

Failure with paired
volumes

R-VOL has been suspended because an
unrecoverable failure occurred in the remote copy
connection

xx

6x

D4

SERIOUS

Failure with paired
volumes

Pair suspend due to failure

xx

7x

D4

SERIOUS

Failure with paired
volumes

Abnormal status occurring during ERASE
operation in migration copy

xx

8x

D4

SERIOUS

Failure with paired
volumes

SERVICE level SIM reported from RCU

xx

Cx

D4

MODERATE

Failure with paired
volumes

MODERATE level SIM reported from RCU

xx

Dx

D4

SERIOUS

Failure with paired
volumes

ACUTE/SERIOUS level SIM reported from RCU

xx

Ex

D4

SERIOUS

Failure with paired
volumes

Suspicion of the pair status failure

xx

Fx

D4

SERIOUS

Failure with paired
volumes

Volume used as P-VOL has been suspended
(Unable to restore path)

xx

0x

DC

SERIOUS

Failure with paired
volumes

Volume used as P-VOL has been suspended
(MCU failure detected)

xx

1x

DC

SERIOUS

Failure with paired
volumes

Volume used as P-VOL has been suspended (RCU
failure detected)

xx

2x

DC

SERIOUS

Failure with paired
volumes

Volume used as P-VOL has been suspended
(S-VOL suspension detected)

xx

4x

DC

SERIOUS

Failure with paired
volumes

Volume used as P-VOL has been suspended
(S-VOL pair deletion detected)

xx

5x

DC

26