Replacing, moving, or adding hard drives, Identifying the status of a hard drive, And c – HP Smart Array P600-Controller User Manual
Page 19

Replacing, moving, or adding hard drives 19
Replacing, moving, or adding hard drives
In this section
Identifying the status of a hard drive......................................................................................................... 19
Recognizing hard drive failure................................................................................................................. 20
Replacing hard drives............................................................................................................................. 22
Moving drives and arrays ....................................................................................................................... 25
Adding drives ........................................................................................................................................ 26
Identifying the status of a hard drive
When a drive is configured as a part of an array and connected to a powered-up controller, the
condition of the drive can be determined from the illumination pattern of the hard drive status lights (LEDs).
Online/activity
LED (green)
Fault/UID LED
(amber/blue)
Interpretation
On, off, or flashing Alternating amber
and blue
The drive has failed, or a predictive failure alert has been
received for this drive; it also has been selected by a
management application.
On, off, or flashing Steadily blue
The drive is operating normally, and it has been selected by a
management application.
On Amber,
flashing
regularly (1 Hz)
A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.
On
Off
The drive is online, but it is not active currently.