Fbwc module and capacitor pack option – HP ProLiant ML350 G6 Server User Manual

Page 80

background image

Hardware options installation 80

IMPORTANT:

The server supports only one battery pack in the chassis. If more than one battery

is needed, use the Velcro strips provided in the option kit to attach additional battery packs.

10.

Install the access panel (on page

27

).

11.

Do one of the following:

o

Close or install the tower bezel, as needed.

o

Slide the server back into the rack.

12.

Power up the server (on page

24

).

For more information, see the documentation that ships with the option.

FBWC module and capacitor pack option

CAUTION:

The cache module connector does not use the industry standard DDR3 mini DIMM

pinout. Do not use this controller with cache modules designed for other controller models,
because the controller can malfunction and you can lose data. Also, do not transfer this cache

module to an unsupported controller model, because you can lose data.

To install the component:

1.

Back up all data.

2.

Close all applications.

3.

Power down the server (on page

24

).

CAUTION:

In systems that use external data storage, be sure that the server is the first unit to be

powered down and the last to be powered back up. Taking this precaution ensures that the system
does not erroneously mark the drives as failed when the server is powered up.

4.

Do one of the following:

o

Open or remove the tower bezel, as needed ("

Open or remove the tower bezel

" on page

25

).

o

Extend the server from the rack (on page

24

).

5.

Remove the access panel (on page

26

).