Server specifications, Environmental specifications, Mechanical specifications – HP ProLiant ML350 G6 Server User Manual
Page 128: Power supply specifications

Server specifications 128
Server specifications
Environmental specifications
Specification
Value
Temperature range*
Operating
10°C to 35°C (50°F to 95°F)
Shipping
-40°C to 70°C (-40°F to 158°F)
Maximum wet bulb temperature 28°C (82.4°F)
Relative humidity
(noncondensing)**
Operating
10% to 90%
Non operating
5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 kPa.
Mechanical specifications
Specification
Value
Dimension
Height (without tower feet)
44.45 cm (17.50 in)
Height (with tower feet)
46.70 cm (18.38 in)
Depth (with tower bezel)
60.00 cm (23.60 in)
Width
22.00 cm (8.66 in)
Weight (no drives installed)
27.22 kg (60.00 lb)
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
•
HP ProLiant 1200 W Power Supply
Specification
Value
Input requirements
Rated input voltage
100 to 120 VAC, 200 to
240 VAC
Rated input frequency
50 Hz to 60 Hz
Rated input current
10 A at 100 VAC
4.9 A at 200 VAC