beautypg.com

Eight-bay sff drive cage option – HP ProLiant ML350 G6 Server User Manual

Page 57

background image

Hardware options installation 57

Eight-bay SFF drive cage option

Before installing the optional SFF hard drive cage, you must install an optional SAS controller. See the
instructions that ship with the option.

CAUTION:

To avoid damage to the pin connectors, install only supported hard drive cages and

components in HP ProLiant ML350 G6 Servers. For supported options, see the QuickSpecs at the
HP website (

http://www.hp.com/servers/proliantml350

).

To install the component:

1.

Install the hard drive expansion cage power cable ("

Installing a hard drive expansion cage power

cable

" on page

54

).

2.

Remove the two bezel blanks closest to the primary hard drive cage.

3.

Using a T-15 Torx screwdriver, remove the sleeve from the optional hard drive cage.

4.

Connect the SAS cables to the optional hard drive cage.