Environmental specifications

Specification

Value

Temperature range*

Operating

10°C to 35°C (50°F to 95°F)

Shipping

-40°C to 70°C (-40°F to 158°F)

Maximum wet bulb temperature 28°C (82.4°F)
Relative humidity
(noncondensing)**

Operating

10% to 90%

Nonoperating

5% to 95%

* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3,048

m (10,000 ft) is applicable. No direct sunlight allowed.

** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 kPa.

Hot-plug power supply calculations

For hot-plug power supply specifications and calculators to determine electrical and heat loading for the

server, see the HP Power Advisor website (

http://www.hp.com/go/hppoweradvisor

).