Rmf pprc link-path statistical information support – HP StorageWorks XP Remote Web Console Software User Manual
Page 47

(GF22-5114); and Geographically Dispersed Parallel Sysplex: the S/390 Multi-site Application
Availability Solution (GF22-5063).
RMF PPRC Link-path Statistical Information Support
When you use Mainframe Resource Measurement Facility (RMF), and if you specify the IBM
TotalStorage Enterprise Storage Server (ESS), you can acquire the PPRC Fibre Link-path statistical
information. For further information on the PPRC Link-path statistical information acquisition, see
the IBM publications.
and
“SAID Values for the LINK Parameters (=ports) of RMF PPRC Link-path Statistical
Information (REAR CL2)” (page 48)
give the HP disk array adaptor ID (SAID) values for the LINK
parameters (ports) that are displayed when you acquire the PPRC Link-path statistical information
using RMF.
The HP disk array adaptor ID (SAID) values in
“SAID Values for the LINK Parameters (=ports) of
RMF PPRC Link-path Statistical Information (FRONT CL1)” (page 47)
and
Parameters (=ports) of RMF PPRC Link-path Statistical Information (REAR CL2)” (page 48)
are
different from the ones for the LINK parameters of CESTPATH TSO commands (see
for the PATH LINK Parameter (= ports) (FRONT CL1)” (page 41)
and
LINK Parameter (= ports) (REAR CL2)” (page 42)
).
If you acquire the PPRC Fibre Link-path statistical information by using RMF, and if the total data
size per the interval for which you acquire the data is 100 kB and below, zero may be reported
for the data size. Even if the data is not updated by host I/O during TrueCopy for Mainframe
Asynchronous operations, the data size is reported. This is because the recordset which does not
have data is sent from MCU to RCU. In this case, if the total data size per the interval for which
you acquire the data is 100 kB and below, zero may also be reported for the data size.
Table 17 SAID Values for the LINK Parameters (=ports) of RMF PPRC Link-path Statistical Information (FRONT
CL1)
1
SAID
Port
Package
Location
SAID
Port
Package
Location
SAID
Port
Package
Location
SAID
Port
Package
Location
X'0048'
CL9-E
1BU
3
X'0068'
CL9-N
1KU
X'0020'
CL1-J
1GU
X'0000'
CL1-A
1EU
2
X'0049'
CLB-E
(Add14)
X'0069'
CLB-N
(Add10)
X'0021'
CL3-J
(Add4)
X'0001'
CL3-A
(Basic)
X'004a'
CLD-E
X'006a'
CLD-N
X'0022'
CL5-J
X'0002'
CL5-A
X'004b'
CLF-E
X'006b'
CLF-N
X'0023'
CL7-J
X'0003'
CL7-A
X'004c'
CL9-F
X'006c'
CL9-P
X'0024'
CL1-K
X'0004'
CL1-B
X'004d'
CLB-F
X'006d'
CLB-P
X'0025'
CL3-K
X'0005'
CL3-B
X'004e'
CLD-F
X'006e'
CLD-P
X'0026'
CL5-K
X'0006'
CL5-B
X'004f'
CLF-F
X'006f'
CLF-P
X'0027'
CL7-K
X'0007'
CL7-B
X'0058'
CL9-G
1BL
X'0078'
CL9-Q
1KL
X'0030'
CL1-L
1GL
X'00010'
CL1-C
1EL
X'0059'
CLB-G
(Add12)
X'0079'
CLB-Q
(Add8)
X'0031'
CL3-L
(Add6)
X'0011'
CL3-C
(Add2)
X'005A'
CLD-G
X'007A'
CLD-Q
X'0032'
CL5-L
X'0012'
CL5-C
X'005B'
CLF-G
X'007B'
CLF-Q
X'0033'
CL7-L
X'0013'
CL7-C
X'005C'
CL9-H
X'007C'
CL9-R
X'0034'
CL1-M
X'0014'
CL1-D
X'005D'
CLB-H
X'007D'
CLB-R
X'0035'
CL3-M
X'0015'
CL3-D
X'005E'
CLD-H
X'007E'
CLD-R
X'0036'
CL5-M
X'0016'
CL5-D
PPRC Support
47