Suspend pairs – HP StorageWorks XP Remote Web Console Software User Manual
Page 233

To release an entire group by force (release mode = 1), you must specify G.
◦
When one volume is specified, the default = C/T under these conditions:
Volume is an R-VOL, release mode = 0, and pair status is not Suspending or Deleting.
•
Time-Saving Mode flag: “Yes” = The Use Time-Saving Mode option is enabled;
“No” = The Use Time-Saving Mode option is disabled; default = “Yes”. This parameter is a
non-list type and only one value can be specified.
“DeleteHrcPair Command” (page 233)
provides an example of the pair macro commands needed
to release the specified pair with release mode = normal.
Example 13 DeleteHrcPair Command
Start $Script="HRC",$Svr="64002"
// $Dev
SetList $D =_ilDevA, $S = {0x000800,0x000901,0x000A02}
AddList $D =_ilDevA, $S = {0x000B03,0x000C04,0x000D05,0x000E06}
// $DelMode
SetList $D = _ilWorkA, $S = {0, 1, 0}
DeleteHrcPair $Dev = _ilDevA, $DelMode = _ilWorkA
DeleteHrcPair $Dev = 0x124C, $DelRange = "Group"
End
Suspend Pairs
The SuspendHrcPair command allows you to suspend TrueCopy for Mainframe pairs. The
SuspendHrcPair parameters include:
SuspendHrcPair $Dev= Device list
[,$SusMode= Suspend mode list]
[,$SusReport= Flag list]
[,$SusRange= Suspend range list]
[,$PendData= Pending data flag list]
[,$TimeSave= Time-Saving Mode flag]
The Details for the arguments are:
•
Device list (numeric): L x 0x10000 + C x 0x100 + VV, where L=LDKC#, C=CU#, VV=vol#
within the CU.
When you write device list, you can omit LDKC# if the LDKC# is 0. For example, you can
write 0x0102 when LDKC# is 0, CU# is 1, and vol# is 2.
•
Suspend mode list (string): “M” or “M-Vol” = M-VOL failure, “R” or “R-Vol” = R-VOL; default
= R-VOL. You must specify R or omit this parameter when suspending async pairs.
•
Flag list (numeric): suspend report flag: 0 = reports; 1 = no reports; default = 1.
•
Suspend range list (string): “G” or “Group” = group; “V” or “Volume” = volume. For sync
pairs you must omit this parameter.
◦
When one volume is specified, the default = G. To suspend only one async pair, you
must specify V.
◦
When two or more volumes are specified, the default = V. When two or more volumes
are specified, you must either specify V or omit this parameter.
Operation Macro Commands 233