HP StorageWorks XP Remote Web Console Software User Manual
Page 192

Table 57 TrueCopy for Mainframe Operations versus PPRC TSO and ICKDSF Commands
Description
Command
Issued to:
ICKDSF Command
TSO Command
TrueCopy for
Mainframe
Operation
If system option mode 114
is OFF, the ports must be
configured using the TC-MF
software. If system option
mode 114 is ON, the ports
are configured
automatically (RCU
target/initiator to
initiator/RCU target) in
response to the CESTPATH
and CDELPATH TSO
commands. However, even
if you set ON for system
option mode 114, initiator
ports will not automatically
change to RCU target
ports, or vice versa, when
these ports are in
initiator/external mix
mode.
For Fibre Channel
interface, do not use the
CESTPATH and CDELPATH
commands at the same time
as the SCSI path definition
function of LUN Manager.
The Fibre Channel interface
ports need to be configured
as initiator ports or RCU
target ports before the
CESTPATH and CDELPATH
commands are issued.
—
—
Configure Port (RCU
target to initiator)
Establishes logical paths
from an MCU to an RCU.
The default RCU options
are used.
MCU
PPRCOPY ESTPATH
CESTPATH
Add RCU
Deletes all active paths
between an MCU and an
RCU.
M-VOL
PPRCOPY DELPATH
CDELPATH
Delete RCU
Displays the status of all
paths for the CU specified
by the DEVN parameter.
TrueCopy for Mainframe
supports the optional
FORMAT/UNFORMAT and
VOLUME/PATHS
parameters.
MCU
PPRCOPY QUERY/
PATHS
CQUERY/PATHS
RCU Status
The default TrueCopy for
Mainframe async options
are used.
MCU/RCU
—
—
Async Options
Must be performed using
the TrueCopy for
Mainframe software. The
group options are selected
during add group.
MCU
—
—
Add Group
192 Using PPRC Commands for TrueCopy for Mainframe