Optional script parameters – HP StorageWorks XP Remote Web Console Software User Manual
Page 245

Table 85 Reserved Status Variables (continued)
Description
Type
Variable
Stores the M-VOL fence level: “Never”
= no fence; “Status” = fence due to an
R-VOL status change failure; “Data” =
fence due to a data error; “Undefined”
= undefined.
String
_HrcStatus _Fence
Stores the synchronous level:
“Synchronous0” = sync;
“Synchronous2” = async; “Undefined”
= undefined.
String
_HrcStatus _Sync
Stores the pair status update time:
“MM/DD/YYYY hh:mm:ss” = MM:
month, DD: day, YYYY: year, hh: hour,
mm: minute, ss: second.
String
_HrcStatus _TimeOfUpdate
Stores the pair creation update time:
“MM/DD/YYYY hh:mm:ss” = MM:
month, DD: day, YYYY: year, hh: hour,
mm: minute, ss: second.
String
_HrcStatus _TimeOfEstablish
Stores the copy progress ratio (0 –
100).
Numeric
_HrcStatus _CopyRatio
Stores the internal status code.
Numeric
_HrcStatus _InternalStatus
Stores the timer type of the consistency
group: “System” = system timer; “Local”
= local (SVP) timer; “None” = no timer;
“Undefined” = undefined.
String
_HrcStatusTypeOfCT
Stores the consistency group number:
0x00-0x7F.
Numeric
_HrcStatus_CTG
Stores the async suspension status:
“Group” = consistency time of
suspended volume matches consistency
time of group; “Volume” = consistency
time of suspended volume does not
match the group consistency time;
“Undefined” = undefined.
String
_HrcStatus_SuspendBy
Stores the error level (async) pair
option: “Group” = all volumes in the
group will be suspended if this volume
is suspended; “Volume” = this volume
will be suspended individually;
“Undefined” = undefined.
String
_HrcStatus_ErrLv
Optional Script Parameters
The parameters outlined in
“Syntax Requirements for Optional Parameters” (page 246)
are optional
parameters that can be added to a script at the script creator's discretion. If any of these parameters
are included in a script, the HP disk array will perform a syntactical check of the script to ensure
that the syntax requirements for the parameter have been met. If no optional parameters are
included, HP disk array will not check any part of the script. HP disk array will run the script
commands based only on what has been specified in the text of the script.
for Optional Parameters” (page 246)
describes the syntax requirements that will be evaluated.
Optional Script Parameters 245