HP XP7 Storage User Manual
Page 81

S-VOL access
P-VOL access
Description
BCM status
RWC status
SWAPPING
(04):
Read/Write
The pair has been suspended by the user and the P-VOL
and S-VOL are no longer synchronized.
SUSPOP (03),
SUSPOP (04),
SWAPPING (04),
SUSPER (07)
Suspend
Read/Write.
All others:
•
The primary and secondary systems keep track of
journal data discarded during the suspend
operation.
Read Only if
Mode=20 is
•
In RWC, when the operation is performed on the
primary system, the status of both the P-VOL and
S-VOL changes to Suspend.
ON, otherwise
No.
•
In RWC, when the operation is performed on the
secondary system, the status of the S-VOL changes
to Suspend; the primary system detects this and
changes P-VOL status to Suspend.
BCM suspend statuses initiated by the user:
•
SUSPOP (03): The user performed a split operation
on the P-VOL. The update information is not reflected
in S-VOL.
•
SUSPOP (04): The user performed a split operation
on the S-VOL. The P-VOL can be updated, and the
update information is recorded as differential data.
•
SWAPPING (04): The pair was split in the REVERSE
direction (S-VOL to P-VOL).
•
SUSPER (07): The P-VOL was split by the system
because the user deleted the pair from the S-VOL
side.
See also
Read Only if
Mode=20 is
Read/Write
The pair is suspended by the system due to an error;
it is not synchronized.
SUSPOP (05),
SUSPCU (06),
SUSPCU (08),
Suspend
ON, otherwise
No.
•
The primary and secondary systems keep track of
journal data discarded during the suspension
operation.
SUSPER (09), SUSPER
(50)
•
The primary system keeps track of P-VOL tracks that
are updated while the pair is suspended.
•
In RWC, when a Cnt Ac-J Z suspension condition
is detected, the primary system changes P-VOL and
S-VOL status to Suspend. If the secondary system
detects the condition, it changes the S-VOL status
to Suspend; the primary system detects this and
changes P-VOL status to Suspend.
BCM suspend statuses initiated by the primary or
secondary system:
•
SUSPOP (05): The secondary system received a
split request from the primary system and split the
pair.
•
SUSPCU (06): The primary system split the pair
because it detected an error in the secondary
system.
•
SUSPCU (08): The pair was split because the
primary system detected an error during
communication with the secondary system or
detected an I/O error during update copy.
•
SUSPER (09): The pair was split because the
primary system detected volatilization of pair control
information on memory when power was ON
(IMPL). This error occurs when power-off status of
Monitoring pair activity, status, license capacity