HP XP7 Storage User Manual
Page 130

Continuous Access Journal Z SIMs are displayed in the Remote Web Console Status window.
•
SIMs generated by the primary system include the P-VOL device ID (byte 13).
•
SIMs generated by the secondary system include the S-VOL device ID (byte 13).
The figure below shows a typical 32-byte SIM from the system. The six-digit reference code consists
of bytes 22, 23, and 13. The reference code identifies the possible error and determines the
severity. The SIM type (byte 28) indicates the component that experienced the error. When the
value of byte 22 is 21, the SIM is a control unit SIM. When the value of byte 22 is Dx (where x
is an arbitrary character), the SIM is a device SIM.
Figure 17 Typical SIM with reference code and SIM type
The following table shows SIM reference codes, and provides useful information for identifying
issues and determining the system experiencing the problem. All SIMs are reported to the host,
except 21 80, 21 81, and possibly DC EX—depending on the value set for system option mode
598. For more information, see
“System option modes ” (page 37)
.
SVP log file
System generating the
SIM
Description
Severity
Reference code
Byte 23
Byte 22
SIM Log
Local/Remote
A remote path is blocked due to failure.
Moderate
80
21
SSB Log
Local/Remote
The remote path is restored.
Service
81
21
SIM Log
Local/Remote
A line failure is reported by the extender.
Moderate
82
21
SIM Log
Local
The P-VOL has been suspended.
Serious
0X
DC
Path recovery is impossible.
SIM Log
Local
The P-VOL has been suspended.
Serious
1X
DC
A failure has been detected in the primary
system.
SIM Log
Local
The P-VOL has been suspended.
Serious
2X
DC
A failure has been detected in the
secondary system.
SIM Log
Local
The P-VOL has been suspended.
Serious
4X
DC
The pair has been suspended at the
secondary system.
SIM Log
Local
The P-VOL has been suspended.
Serious
5X
DC
A pair has been released at the
secondary system.
SIM Log
Local
The S-VOL has been suspended.
Serious
6X
DC
Path recovery is impossible.
SIM Log
Remote
The S-VOL has been suspended.
Serious
7X
DC
A failure has been detected in the
secondary system.
130 Cnt Ac-J Z troubleshooting